Pharmacokinetics (PK) describes what the body does to a drug over time. A bioequivalence study is a PK study that compares a test product with a reference product and shows that their rate and extent of absorption are close enough to be considered the same.
Free sandbox · No credit card · 21 CFR Part 11 compliant
Bioequivalence study
noun · clinical research
A comparative PK study, usually a randomised crossover, in which the 90% confidence interval of the test-to-reference geometric mean ratio for Cmax and AUC must fall within 80.00-125.00%.
Related terms
In short
Pharmacokinetics
After a dose, a drug is absorbed, distributed into tissues, metabolised and excreted. A PK study captures this by taking blood samples at fixed times, measuring the drug concentration with a validated bioanalytical method, and plotting concentration against time. The shape of that curve is summarised in a handful of parameters, usually calculated by non-compartmental analysis.
PK appears throughout development. In a first-in-human study it tells the team how exposure rises with dose. Alongside pharmacodynamics, it links exposure to effect. Later it supports drug interaction, food-effect and special-population studies. A bioequivalence study is the most regulated use of PK, because its result can replace clinical efficacy trials for a generic or a new formulation.
These are the parameters most often reported and the ones bioequivalence decisions rest on.
| Assessment | Pre-dose | 0 h | 0.5 h | 1 h | 2 h | 4 h | 8 h | 24 h | 48 h |
|---|---|---|---|---|---|---|---|---|---|
| Dose administered | |||||||||
| PK blood sample | |||||||||
| Vital signs | |||||||||
| Adverse events |
Demo data only. Times relative to dosing at 0 h; real schedules come from the protocol.
Bioequivalence
Bioequivalence asks whether a test product (for example a generic, or a new tablet strength) delivers the same exposure as a reference product. PK parameters are log-normally distributed, so the analysis works on log-transformed Cmax and AUC. An analysis of variance on the log scale gives the difference between treatments and its 90% confidence interval, which is back-transformed into a ratio of geometric means.
The acceptance rule is the same in FDA and EMA guidance for most products: the 90% confidence interval of the test/reference geometric mean ratio must lie entirely within 80.00% to 125.00%. The range looks asymmetric because it is symmetric on the log scale (125% is the reciprocal of 80%). A point estimate of 100% is not enough; a study that is too small can have a ratio near 100% and still fail because the interval is too wide. Sizing for this is covered by the crossover sample size calculator and the equivalence sample size calculator.
The usual design randomises participants, often healthy volunteers, to one of two sequences: test then reference, or reference then test. Each participant gets both products, so between-person variability drops out of the comparison. Between periods comes a washout. EMA’s bioequivalence guideline says that normally at least five elimination half-lives are needed, and it expects participants whose pre-dose concentration in the second period is above 5% of their Cmax to be excluded from the analysis. ICH M13A now supersedes parts of that guideline for immediate-release oral products; check the current text for your product and region.
Highly variable drugs can need replicate designs, where the reference product is given more than once and the acceptance range may be widened based on its variability under specific conditions. Narrow therapeutic index drugs may need tighter limits. Long half-life drugs may use a parallel design instead of a crossover. These choices are set by product-specific guidance and should be agreed before the protocol is final.
| GMR | 90% CI | Within 80-125%? | |
|---|---|---|---|
| Cmax | 96.4% | 88.9-104.5% | |
| AUC0-t | 101.2% | 95.7-107.0% | |
| AUC0-inf | 100.8% | 95.1-106.8% |
Running one
Eligible participants are randomised to TR or RT. Allocation must be concealed and documented (randomization).
The first product is given under standardised conditions (fasting or fed as specified). Dosing time and each sample time are recorded to the minute.
Participants leave the unit or stay under observation for the protocol washout, sized from the drug’s half-life.
The other product is given, with a pre-dose sample to check that the first dose has cleared.
Samples are assayed, PK parameters calculated, and the 90% confidence intervals compared with the 80.00-125.00% limits.
Build dosing and sampling forms with date-time fields in the free sandbox, add edit checks on sample timing, and run a test export. No credit card, no time limit.
In Capture
In a BE study the clinical data is mostly timing: when the dose was given, when each sample was drawn, and whether anything happened in between. In Capture you build date and time fields for dosing and each sample, use the built-in calculated field for minutes or hours between two date-times to show elapsed time read-only during entry, and add edit checks that raise an auto-query when a sample falls outside its window. Repeating table rows hold one row per sample, each with its own audit trail. Exports come as CSV or Excel with a data dictionary, or as SDTM datasets (SAS XPT with Define-XML).
Dose date and time
EXSTDTCNominal time point
PCTPTActual sample time
PCDTCElapsed since dose (min)
A comparative pharmacokinetic study, usually a randomised crossover in healthy volunteers, that shows a test product and a reference product produce exposure close enough that they can be expected to have the same effect.
It allows up to a 20% difference, applied on the log scale where PK data is analysed. On the log scale the limits are symmetric, and 125% is the reciprocal of 80%.
The whole 90% confidence interval of the geometric mean ratio for each primary parameter, usually Cmax and AUC, must lie within the limits.
Long enough that the first dose has cleared before the second period. EMA guidance says normally at least five elimination half-lives. Check the guidance that applies to your product.
Usually not as a formal criterion for immediate-release products, but it is reported and compared, and some product-specific guidances give it more weight.
Pharmacokinetics is the science of drug concentration over time. Bioequivalence is one application of it: a pre-defined statistical comparison of PK parameters between two products.
Keep exploring
EDC for bioequivalence studies
Data capture for BE trials.
Crossover sample size calculator
Size a two-period study.
Pharmacodynamics
What the drug does to the body.
First-in-human study
Where PK is first measured.
EDC for healthy volunteer studies
Typical BE population.
Equivalence sample size calculator
Margins and power.
Free sandbox with every feature. Build dosing and sampling forms, test edit checks on time windows and export. No credit card, no time limit.