Glossary · Study designUpdated November 27, 2026

Pharmacokinetics and bioequivalence: study definition and design

Pharmacokinetics (PK) describes what the body does to a drug over time. A bioequivalence study is a PK study that compares a test product with a reference product and shows that their rate and extent of absorption are close enough to be considered the same.

  • Bioequivalence in plain language
  • How it works in practice
  • Related terms

Free sandbox · No credit card · 21 CFR Part 11 compliant

  • ISO 27001 certified
  • 21 CFR Part 11 compliant
  • GDPR compliant
  • EU and US data hosting
  • HIPAA compliant
  • ICH GCP E6(R3) compliant
PharmacokineticsBE

Bioequivalence study

noun · clinical research

A comparative PK study, usually a randomised crossover, in which the 90% confidence interval of the test-to-reference geometric mean ratio for Cmax and AUC must fall within 80.00-125.00%.

Related terms

CmaxAUCTmaxHalf-lifeCrossover designWashout

In short

  • PK follows a drug through absorption, distribution, metabolism and excretion by measuring concentrations in blood or plasma at planned times after a dose.
  • The main parameters are Cmax (peak concentration), Tmax (time to peak), AUC (total exposure) and t½ (elimination half-life).
  • Two products are bioequivalent when the 90% confidence interval of the test/reference geometric mean ratio for Cmax and AUC lies within 80.00-125.00%.
  • The standard design is a randomised two-period, two-sequence crossover, so each participant is their own control, with a washout long enough for the first dose to clear.
  • Results depend on exact timing: actual dose and sample times, not just nominal ones, have to be captured.

Pharmacokinetics

What PK measures

After a dose, a drug is absorbed, distributed into tissues, metabolised and excreted. A PK study captures this by taking blood samples at fixed times, measuring the drug concentration with a validated bioanalytical method, and plotting concentration against time. The shape of that curve is summarised in a handful of parameters, usually calculated by non-compartmental analysis.

PK appears throughout development. In a first-in-human study it tells the team how exposure rises with dose. Alongside pharmacodynamics, it links exposure to effect. Later it supports drug interaction, food-effect and special-population studies. A bioequivalence study is the most regulated use of PK, because its result can replace clinical efficacy trials for a generic or a new formulation.

Core PK parameters

These are the parameters most often reported and the ones bioequivalence decisions rest on.

  • Cmax: the highest observed concentration. Reflects rate and extent of absorption.
  • Tmax: the time at which Cmax is observed. Compared descriptively in most BE studies.
  • AUC0-t: area under the concentration-time curve from dosing to the last measurable concentration. The main measure of extent of exposure.
  • AUC0-inf: AUC extrapolated to infinity using the terminal elimination rate (λz).
  • t½: terminal half-life, the time for the concentration to fall by half. Drives washout length and dosing interval.
  • CL/F and Vz/F: apparent clearance and volume of distribution after oral dosing.
PK sampling, one period of a BE study (demo)
AssessmentPre-dose0 h0.5 h1 h2 h4 h8 h24 h48 h
Dose administered
PK blood sample
Vital signs
Adverse events

Demo data only. Times relative to dosing at 0 h; real schedules come from the protocol.

Dense samples around the expected Tmax, then spaced out to define the terminal phase.

Bioequivalence

How bioequivalence is shown

Bioequivalence asks whether a test product (for example a generic, or a new tablet strength) delivers the same exposure as a reference product. PK parameters are log-normally distributed, so the analysis works on log-transformed Cmax and AUC. An analysis of variance on the log scale gives the difference between treatments and its 90% confidence interval, which is back-transformed into a ratio of geometric means.

The acceptance rule is the same in FDA and EMA guidance for most products: the 90% confidence interval of the test/reference geometric mean ratio must lie entirely within 80.00% to 125.00%. The range looks asymmetric because it is symmetric on the log scale (125% is the reciprocal of 80%). A point estimate of 100% is not enough; a study that is too small can have a ratio near 100% and still fail because the interval is too wide. Sizing for this is covered by the crossover sample size calculator and the equivalence sample size calculator.

Crossover design and washout

The usual design randomises participants, often healthy volunteers, to one of two sequences: test then reference, or reference then test. Each participant gets both products, so between-person variability drops out of the comparison. Between periods comes a washout. EMA’s bioequivalence guideline says that normally at least five elimination half-lives are needed, and it expects participants whose pre-dose concentration in the second period is above 5% of their Cmax to be excluded from the analysis. ICH M13A now supersedes parts of that guideline for immediate-release oral products; check the current text for your product and region.

When the standard design is not enough

Highly variable drugs can need replicate designs, where the reference product is given more than once and the acceptance range may be widened based on its variability under specific conditions. Narrow therapeutic index drugs may need tighter limits. Long half-life drugs may use a parallel design instead of a crossover. These choices are set by product-specific guidance and should be agreed before the protocol is final.

Demo BE result, DEMO-101 (test vs reference)
GMR90% CIWithin 80-125%?
Cmax96.4%88.9-104.5%
AUC0-t101.2%95.7-107.0%
AUC0-inf100.8%95.1-106.8%
Demo numbers for illustration only, not from a real study.

Running one

How a two-period crossover BE study runs

  1. 1

    Screen and randomise to a sequence

    Eligible participants are randomised to TR or RT. Allocation must be concealed and documented (randomization).

  2. 2

    Period 1: dose and sample

    The first product is given under standardised conditions (fasting or fed as specified). Dosing time and each sample time are recorded to the minute.

  3. 3

    Washout

    Participants leave the unit or stay under observation for the protocol washout, sized from the drug’s half-life.

  4. 4

    Period 2: cross over

    The other product is given, with a pre-dose sample to check that the first dose has cleared.

  5. 5

    Bioanalysis and statistics

    Samples are assayed, PK parameters calculated, and the 90% confidence intervals compared with the 80.00-125.00% limits.

Test your PK sampling forms before period 1

Build dosing and sampling forms with date-time fields in the free sandbox, add edit checks on sample timing, and run a test export. No credit card, no time limit.

Try Capture free

In Capture

Exact times, clean exports

In a BE study the clinical data is mostly timing: when the dose was given, when each sample was drawn, and whether anything happened in between. In Capture you build date and time fields for dosing and each sample, use the built-in calculated field for minutes or hours between two date-times to show elapsed time read-only during entry, and add edit checks that raise an auto-query when a sample falls outside its window. Repeating table rows hold one row per sample, each with its own audit trail. Exports come as CSV or Excel with a data dictionary, or as SDTM datasets (SAS XPT with Define-XML).

  • Date and time fields with elapsed-time calculations.
  • Edit checks and auto-queries on sampling windows.
  • Randomization and field-level audit trail in the same system.
EDC for bioequivalence studies
PK sampling log
DEMO-101 · Subject 001-0042 · Period 1 (Test)In progress

Dose date and time

EXSTDTC
2026-04-02 08:00

Nominal time point

PCTPT
2 h

Actual sample time

PCDTC
10:07

Elapsed since dose (min)

127 Calculated
Demo data only.Save
Sample 7 min late: inside the demo window of ±10 min, so no query.

FAQ

Common questions

Something not covered here? Ask us directly.

What is a bioequivalence study?

A comparative pharmacokinetic study, usually a randomised crossover in healthy volunteers, that shows a test product and a reference product produce exposure close enough that they can be expected to have the same effect.

Why is the bioequivalence range 80-125%?

It allows up to a 20% difference, applied on the log scale where PK data is analysed. On the log scale the limits are symmetric, and 125% is the reciprocal of 80%.

Is it the point estimate or the confidence interval that must be in 80-125%?

The whole 90% confidence interval of the geometric mean ratio for each primary parameter, usually Cmax and AUC, must lie within the limits.

How long should the washout be?

Long enough that the first dose has cleared before the second period. EMA guidance says normally at least five elimination half-lives. Check the guidance that applies to your product.

Is Tmax part of the bioequivalence decision?

Usually not as a formal criterion for immediate-release products, but it is reported and compared, and some product-specific guidances give it more weight.

What is the difference between pharmacokinetics and bioequivalence?

Pharmacokinetics is the science of drug concentration over time. Bioequivalence is one application of it: a pre-defined statistical comparison of PK parameters between two products.

Rehearse your BE study timing

Free sandbox with every feature. Build dosing and sampling forms, test edit checks on time windows and export. No credit card, no time limit.

Try Capture free