Glossary · Monitoring and qualityUpdated November 27, 2026

Source documents and source data in clinical trials

Source data are the original records of what was observed in a clinical trial: the first place a blood pressure, a symptom or a consent date was written down or captured. Source documents (source records in ICH E6(R3)) are where those data live, and they are what the case report form is checked against.

  • Source data in plain language
  • How it works in practice
  • Related terms

Free sandbox · No credit card · 21 CFR Part 11 compliant

  • ISO 27001 certified
  • 21 CFR Part 11 compliant
  • GDPR compliant
  • EU and US data hosting
  • HIPAA compliant
  • ICH GCP E6(R3) compliant
Data integrity

Source data

noun · clinical research

All information in original records, and certified copies of original records, of clinical findings, observations or other activities in a trial that is needed to reconstruct and evaluate the trial.

Related terms

Source recordsCertified copyALCOA+eSourceSDV

In short

  • Source data are the first recording of an observation. Source documents (E6(R2)) or source records (E6(R3)) are where they are kept: medical notes, lab reports, ECG printouts, participant diaries, pharmacy records, device outputs.
  • A certified copy can stand in for the original if it has been verified as complete and accurate, including metadata.
  • The CRF is not usually source. It is a transcription of source, unless data are entered directly and the protocol says the eCRF is the source for that item.
  • Source must meet ALCOA+: attributable, legible, contemporaneous, original, accurate, plus complete, consistent, enduring and available.
  • Monitors check CRF data against source through source data verification (SDV) and review source for quality and compliance through source data review (SDR).

Explained

What counts as source

ICH GCP defines source data as the information in original records, and certified copies of them, needed to reconstruct and evaluate the trial. E6(R2) called the containers source documents and gave examples such as hospital records, clinical and office charts, laboratory notes, participant diaries, pharmacy dispensing records, recorded data from automated instruments, and X-rays. E6(R3) speaks of source records, original documents or data including relevant metadata, irrespective of the media used, which recognises that much source is now electronic. Check the current ICH E6(R3) glossary for the exact wording.

The test is simple to state: where was this value first recorded? If the coordinator measured a blood pressure and wrote it on a worksheet before typing it into the EDC, the worksheet is source and the case report form holds a copy. If the value went straight from the device into an electronic record, that electronic record is source. If the coordinator typed it directly into the eCRF with no earlier record, the eCRF entry is source for that item.

Defining the source in advance

Ambiguity about source causes most source-related inspection findings. Good practice is to agree, before the first participant, where each data item is first recorded at each site, often in a source data location list or agreement filed in the site file. That list says, for example, that vital signs are source in the hospital record, questionnaire scores are source in the ePRO system, and the eligibility checklist is source on a site worksheet.

eSource

Electronic source is data first captured electronically: an electronic health record, a direct-entry eCRF, an ePRO diary completed by the participant, a wearable or instrument output. Regulators accept eSource when the system and process protect the data, including an audit trail, access control and the ability for monitors and inspectors to see the original. See eSource for sites and EDC versus eSource.

Source data location list (demo site 001, DEMO-101)
Source locationTranscribed to eCRF?
Vital signsHospital record
Central lab resultsLab report
Daily symptom diaryePRO entry by participant
Eligibility checklisteCRF (direct entry)
Consent date and versionSigned consent form
Concomitant medicationsClinic notes
Demo data only. Your list comes from the protocol and each site's practice.

Data integrity

ALCOA+ applied to source

ALCOA+ is the usual shorthand for what regulators expect of trial records. Each letter has a practical meaning for source.

PrincipleWhat it means for source
AttributableYou can tell who recorded the value and, for changes, who changed it.
LegibleIt can be read and understood, now and years later.
ContemporaneousRecorded at the time of the observation, with the date (and time where it matters).
OriginalThe first record, or a certified copy of it.
AccurateCorrect, with corrections that do not obscure the original entry.
Complete, consistent, enduring, availableNothing missing, no contradictions, durable for the retention period, retrievable when asked.

See the ALCOA+ data integrity checklist for a fuller version.

Make direct-entry data hold up as source

Capture records who entered each value, when, and every change with old value, new value and reason. Try it on demo data in the free sandbox. No credit card, no time limit.

Try Capture free

Monitoring

How source is checked: SDV and SDR

Source data verification compares CRF entries with source to confirm transcription was accurate. Source data review goes further: it reviews the source itself for protocol compliance, eligibility, safety signals and quality of documentation, whether or not the value was transcribed. Under risk-based approaches, monitors no longer verify everything; they target critical data and processes. See SDV versus SDR and risk-based monitoring.

Whatever the approach, monitors need access to source, which means the site must be able to show them the original record or a certified copy. Findings from source review are written up in the monitoring visit report, and a missing or late source entry is often explained with a note to file. Strong source practice is checked again at the end of the trial, and the records are kept for the full retention period.

The ALCOA+ data integrity checklist is a quick way to test whether a site's source practice will hold up.

Setup

Getting source right before the first participant

  1. 1

    List every data item in the protocol

    Use the schedule of assessments to list what is collected and when.

  2. 2

    Decide where each item is first recorded

    Hospital record, worksheet, ePRO, direct eCRF entry or device output. Write it down per site.

  3. 3

    Check each source meets ALCOA+

    Attributable, dated, original and retrievable. Electronic systems need an audit trail and controlled access.

  4. 4

    Decide the monitoring approach

    Which items need SDV, which need SDR only, and how monitors will get access to source.

  5. 5

    Train the site and file the agreement

    Make sure everyone on the delegation log knows the source rules, and file the agreed source list in the site file.

In Capture

Audit trail and per-field SDV

In Capture, source data verification can be set per field, so monitors focus on the critical data your monitoring plan names. Every record has a field-level audit trail with timestamp, user identity, old value, new value and reason for change; the audit trail cannot be modified and is always exportable. Edit checks raise an auto-query when a site enters a value that breaks a rule.

  • SDV configurable per field.
  • Field-level audit trail on every record.
  • Auto-queries from edit checks at entry.
Risk-based monitoring and SDV software
Vital signs · SDV configuration
SDV: 3 of 5 fieldsSDV config v3
  • Date of birth
  • Systolic blood pressure
  • Diastolic blood pressure
  • BMI (calculated)never verified
  • Position during measurement
  • Comments

Changed by Data manager · reason: critical safety value added

FAQ

Common questions

Something not covered here? Ask us directly.

What are source documents in clinical trials?

The original records in which trial observations are first captured, such as medical notes, lab reports, ECG printouts, diaries and pharmacy records, or certified copies of them. ICH E6(R3) calls them source records.

What is the difference between source data and the CRF?

Source data are the first record of an observation. The CRF usually holds a transcription of source for the sponsor. Where data are entered directly into the eCRF with no earlier record, the eCRF is the source for those items.

What is a certified copy?

A copy of an original record that has been verified, by a dated signature or a validated process, to have the same information as the original, including relevant context and metadata.

What is eSource?

Source data first captured electronically, for example in an electronic health record, a direct-entry eCRF, an ePRO diary or a device. It needs the same integrity controls as paper source, including an audit trail.

What is the difference between SDV and SDR?

SDV checks that CRF entries match source. SDR reviews the source itself for protocol compliance, safety and documentation quality. Risk-based monitoring combines both in a targeted way.

Can SDV be targeted to certain fields in Capture?

Yes. Source data verification can be set per field in Capture, so monitoring effort goes to the data your monitoring plan marks as critical.

Test per-field SDV on a demo study

Free sandbox with every feature. Build forms, set SDV and check the audit trail. No credit card, no time limit.

Try Capture free