Study type · Drug-device combinationUpdated October 18, 2026

Combination product trial software: drug data and device data in the same casebook

When the product is a drug and a device together, such as an autoinjector, prefilled pen or inhaler, a single injection can generate a pharmacology result, a use experience and possibly a malfunction. This page explains how to capture all three without mixing them up.

  • Use-related data per dose
  • Device deficiency versus adverse event
  • One audit trail

Free sandbox · No credit card · 21 CFR Part 11 aligned

Classifying a report from an autoinjector study · demo
Device problem?Participant harmed?Record as
Cap would not releaseDevice deficiency
Needle shield failed, finger prickDeficiency and AE
Dose delivered, injection site rashAdverse event
Held too briefly, partial dose notedUse difficulty, deficiency review
Instructions misread, wrong dayUse error, protocol deviation review
Demo scenarios. The classification rules come from your protocol and device documentation.

The short answer

  • A combination product brings together a drug, device or biologic in one product. Autoinjectors, prefilled syringes, inhalers, drug-eluting products and some patches are examples. The study has to answer questions about both parts.
  • Three kinds of data have to stay distinct. Drug outcomes (efficacy, pharmacokinetics, adverse events), use-related data (how the participant handled the device), and device performance (deficiencies, malfunctions).
  • A device deficiency is not an adverse event, and an adverse event is not a device deficiency. One incident can be both, one, or neither. Capturing them in separate forms with a link between them is cleaner than one free-text field.
  • Regulatory framing is generic here and needs confirming. In the US, FDA regulates combination products through a lead centre decided by primary mode of action (21 CFR Part 3), and Part 4 sets cGMP and postmarketing safety reporting expectations. Which rules apply to your study is a question for your regulatory team.
  • Capture records the data; it does not connect to devices. There is no device or companion-app integration. Device identifiers and use observations are recorded by staff or participants on forms.
  • Plan the unglamorous parts early: returning the used device for analysis, tracing the lot, and training the participant.

Why this is different

What changes when the product is a drug and a device

A drug trial asks whether the drug works and whether it is safe. A device study asks whether the device performs and whether it can be used safely. A combination product study often asks both, with a third question on top: can the intended users, at home and without a nurse, operate the device correctly to receive the full dose? A perfect drug in a device that people cannot use will fail, which is why use-related data count.

Regulators treat combination products as a category with its own rules. In the US, FDA assigns the product to a lead centre based on its primary mode of action, and regulations in 21 CFR Parts 3 and 4 cover assignment, current good manufacturing practice and postmarketing safety reporting for combination products. Clinical studies may run under an IND, an IDE or both, depending on the product and the regulatory path, and guidance on human factors and usability applies to the device part. In Europe and elsewhere the rules differ. Do not take this page as advice on classification; take it as a data design checklist, and let your regulatory advisor decide the path.

On the data side, the same study often generates the clinical dataset (visits, labs, adverse events), a use dataset (observations and diaries about handling) and a device dataset (identifiers, deficiencies, returns). Hold them in one system with one participant ID so they can be linked. For general device study design, see how to run a medical device clinical study, EDC for medical device clinical trials and early feasibility and pivotal device studies.

Data map

What to capture, where, and who records it

DataExample fieldsWho records itWhen
Device identificationDevice type and model, lot or batch reference, expiry, number of the unit usedSite staff, for supervised doses; participant, for home dosesEvery dose
TrainingDate trained, trainer, method, participant demonstrated correct use (yes or no), repeat training neededSite staffBaseline and when retrained
Supervised dose observationSteps completed in order, difficulty rating, observer comments, time to completeTrained observerFirst doses, per protocol
Home dose diaryDate and time, injection site, heard click or saw indicator, complete dose, any problem, free-text noteParticipant (ePRO)Each home dose
Use difficultiesStep affected, type (unable, delayed, wrong), consequence, whether help was neededParticipant or site staffWhenever it happens
Device deficiencyDescription, date, device reference, consequence, device returned (yes or no), return dateSite staffOn report
Adverse eventsTerm, onset, severity, seriousness, relatedness to drug and to device, action, outcomeSite staffEvery visit and on report
Device return and analysisReturn date, result of the manufacturer's analysis, date receivedStudy coordinatorAfter return

Field names and timing are illustrative. Use your protocol and device documents to settle them.

Home use

Home dosing diaries without an app

Most combination product studies include home doses, so the diary carries the use-related data. With Capture ePRO the participant opens a link on a phone or computer, with no app to install, and answers a few questions after each dose. The question types cover what you need: single choice for the injection site and whether the click was heard, a time field for the dose, a dropdown for problem type and a long text for anything that went wrong.

  • A "did the full dose complete?" question with a follow-up that appears only if the answer is no (skip logic).
  • A problem-type dropdown that maps to your device deficiency categories, so a serious problem flags for staff.
  • Reminders for each scheduled dose, and a visible record of missed diaries.
  • Every entry time-stamped; edits are recorded with old and new value.
See ePRO in Capture

Autoinjector home dose diary

Participant 002-0019 · Dose 7 of 12

Time of injection

INJTM
19:40

Injection site

INJSITE
AbdomenThighUpper arm

Did you hear a click and see the indicator change?

CLICK
YesNoNot sure

Did you have any problem with the device?

PROBTYPE
Leak or wet needle

Study team notified

Describe what happened

PROBDESC

Keep the device if you can

Keep the used device for the study team.Save
Demo diary. Not a real product.

Build the dose diary and the deficiency form

Create both in the free sandbox, run a test participant through twelve doses and see what staff see. Every feature, no credit card, no time limit.

Build a device form free

The hard part

Separating device deficiencies from adverse events

In device studies, a device deficiency is generally understood as an inadequacy of the device in identity, quality, durability, reliability, usability, safety or performance, which includes malfunction and use error, and the standard ISO 14155 on clinical investigation of medical devices uses this idea. An adverse event is any untoward medical occurrence in a participant. The two overlap: a deficiency may or may not cause an event, and an event may or may not involve a deficiency. Your protocol should say how each is reported, to whom and by when, and it should define the terms in the same way for sites, monitors and the safety team.

Practical design follows. First, separate forms: the adverse event form (reusing the standard template) and a device deficiency form. Second, cross-reference fields: the AE form asks "was a device deficiency involved?" and, if yes, which report number; the deficiency form asks "did this lead to an adverse event?" and which one. A pair of edit checks keeps them consistent, so a "yes" on one side without a link on the other raises an auto-query. Third, relatedness to each part: record relatedness to the drug and to the device separately, because the answer drives different follow-up. The AE causality assessment software page covers assessment logic, and adverse event reporting software covers the basics.

Use errors need the same discipline. If the participant gave the wrong dose because the instruction was ambiguous, that is a use-related observation that may feed a human factors analysis and also, under your protocol, a protocol deviation. The protocol deviation tracking software page covers the second half. Be consistent: classify with the same decision tree every time and document how it changed if the protocol is amended.

Reported problem to classified record · demo decision path
  1. Report received

    Diary entry or site call: needle shield issue

  2. Device deficiency form opened

    Description, date, device and lot reference

  3. Participant harmed?

    Yes: minor finger prick

  4. 4

    Adverse event form opened and linked

    Severity mild, related to device

  5. 5

    Device return and analysis

    Returned unit logged; manufacturer analysis awaited

  6. 6

    Reporting decision

    Per protocol and regulatory advice

Demo path. Reporting duties come from your protocol and regulatory advisers.

Two examples

The same pattern in an autoinjector study and an inhaler study

The device differs; the structure of the data capture does not.

Autoinjector

Fixed-dose pen, home use after training

Capture supervised doses on a staff observation form at the first visits, then home doses by diary. Key use data: cap removal, placement, hold time, click and indicator, completeness. Key device data: lot, malfunction, leak, needle shield. Key drug data: pharmacokinetic sampling visits and injection site reactions. See EDC for medical device clinical trials.

Inhaler

Dry powder or metered dose inhaler

Capture technique checks at visits (shake, exhale, inhale, hold) on a staff checklist, plus a diary with symptom scores and puffs used. Key device data: counter reading, blocked mouthpiece, dose counter failure. Key drug data: lung function and exacerbations. The [asthma peak flow diary template](/templates/asthma-peak-flow-diary-epro) is a starting point for the participant diary.

Read more
Control

Comparator device or placebo device

If the comparator uses a different device, build forms that work for both. Do not rely on the device type to classify a problem; collect the same use-related questions in each arm so the comparison is fair.

Setting up

Six steps to configure a combination product study

  1. 1

    Write the three data dictionaries

    List the drug fields, use fields and device fields. For each, decide who completes it and when. Prefer controlled choices to free text.

  2. 2

    Build the standard forms from templates

    Start from the adverse event, concomitant medication, vital signs and demographics templates and add the device forms. Use the AI study builder to draft the visit schedule from your protocol, then review it.

  3. 3

    Create the cross-links

    Add the linking fields between AE and deficiency forms and set the edit checks that raise a query when links are missing.

  4. 4

    Set roles

    Decide who can see treatment assignment, who completes deficiency forms and who can approve closure. Blinded roles never receive treatment-arm values.

  5. 5

    Plan the device returns

    Decide how used devices are returned and who confirms receipt. Capture records the return as data fields; physical tracking is handled in your own process.

  6. 6

    Test with a mock participant

    Walk a mock participant through training, supervised dose, home doses and a deliberately reported problem. Check that the deficiency and AE forms link and the export shows both.

Analysis

Reading the data afterwards

Use-related summaries are often tabulated by step: for each step of the instructions, how many doses were performed correctly, with difficulty, or not at all. Device summaries tabulate deficiencies by type, severity of consequence and whether a returned unit was analysed. Safety summaries show adverse events by relatedness to drug and to device. To produce these, the export needs the device reference, dose number, step results and links between forms. Capture exports CSV and Excel in wide format with a data dictionary and can filter by site or date; SDTM datasets can be produced as SAS XPT with Define-XML for the standard clinical domains. See export EDC data to R, SAS and SPSS.

Capture does not supply a human factors analysis engine, an automatic device failure classification or a device inventory; if you need those, plan for them outside the platform. Keep the blank eCRF PDF for submission packages, and record device documents in your trial master file.

Autoinjector study · home dosing summary · demo

Home doses expected

720

Diaries received

701

Use difficulties

14

Device deficiencies

3

Diaries received701/720
Reported difficulty14/720
Deficiencies with a linked AE1/3

finger prick

Demo values: 60 participants x 12 home doses = 720 expected.

FAQ

Questions teams ask before they switch

Something not covered here? Ask us directly.

What is a combination product?

It is a product made of two or more regulated components, such as a drug and a device, combined or packaged together. Autoinjectors, prefilled syringes, inhalers and drug-eluting devices are common examples.

Does Capture integrate with autoinjectors or smart inhalers?

No. Capture has no device or companion-app integration for these. Use observations and device identifiers are recorded on forms by staff or participants.

How do I record a device malfunction that caused no harm?

Use a device deficiency form with no linked adverse event. Record the description, device and lot reference, whether the unit was returned and the date.

Should use errors be recorded as adverse events?

Not by default. Use errors are use-related observations; they become adverse events only if a participant suffers an untoward medical occurrence. Your protocol decides how each is classified and reported.

Which FDA rules apply to combination products?

In the US, 21 CFR Part 3 covers assignment to a lead centre, and Part 4 covers cGMP and postmarketing safety reporting for combination products. The clinical study may run under an IND, an IDE or both. Ask your regulatory team which applies; this page is not advice.

Can participants record home doses on their phone?

Yes. ePRO runs in the browser from a link, with no app to install, and reminders can be set for each scheduled dose.

Can I run an autoinjector study in Phase 3?

Yes. Capture is suitable for Phase 1 to 3, and device-related data design does not depend on phase. The sample size for use data is set in the protocol.

How do I keep drug and device data linked?

Use one participant ID, one dose number and a device reference on each form, then export a wide file with a data dictionary. Cross-link fields between AE and deficiency forms make the connection explicit.

Build the dose diary and the deficiency form

Open the free sandbox, create a home dose diary and a linked device deficiency and adverse event pair, and walk a mock participant through them. No credit card, and you pay only once you go live.

Build a device form free