A MASH trial reads a liver biopsy, a stiffness measurement and a column of liver enzymes, and has to keep weight, glucose and lipids in view because they move the liver too. Capture holds central histology reads, imaging values, lab tables with safety flags and the metabolic picture in one audit-trailed study. Build it free.
Free sandbox · No credit card · 21 CFR Part 11 compliant
Sample
Biopsy date
MBDTCCore length
CORELENAdequate for scoring
ADEQScores
Steatosis
STEATLobular inflammation
LOBINFHepatocyte ballooning
BALLOONActivity score total
ACTTOTFibrosis stage
FIBSTGWhat a MASH trial needs from its EDC
Biopsy endpoints
Biopsy-based MASH trials usually score each slide with a semi-quantitative system, commonly the one developed by the NASH Clinical Research Network: steatosis 0 to 3, lobular inflammation 0 to 3 and hepatocyte ballooning 0 to 2, summed into an activity score of 0 to 8, and a fibrosis stage from F0 to F4 with sub-stages in some versions. Histology endpoints used in regulatory programmes include resolution of steatohepatitis without worsening of fibrosis, and an improvement of at least one fibrosis stage without worsening of steatohepatitis. Exact definitions, sub-stages and reader rules differ between programmes and guidance updates, so take them from your protocol and the current regulatory text.
Build the read as a site eCRF completed by the pathologist, one per reader per biopsy. Each component is a single-choice field with option scores, and the Scoring & rules tab adds a Sum for the activity total, calculated when the form is saved and included in the export. Add sample adequacy (core length, number of portal tracts if your charter asks for it) and a field for "not evaluable" with a reason. Where two or three pathologists read independently and then agree a consensus, keep each read as its own record and the consensus as a separate form, so the audit trail shows who scored what. Readers should not see the arm or the visit order; blinded roles never receive treatment-arm values in Capture, and the read form can sit in a role that sees nothing but the slide identifier. See blinded and unblinded role management.
Biopsy logistics are the other half: date of biopsy, whether a historical biopsy within a set window was used at screening, the procedure-related adverse events, and the slide shipping log. A window check comparing the biopsy date with the randomisation date raises an auto-query when a historical biopsy is too old. Endpoint status (resolution, improvement, worsening) is calculated from the export by comparing baseline and on-treatment reads.
Protocol to build
| Assessment | What the data looks like | Where it lives in Capture |
|---|---|---|
| Biopsy read | Steatosis, inflammation, ballooning, activity total, fibrosis stage, adequacy, reader | Site eCRF per reader with option scores and Sum; consensus form |
| Elastography | Liver stiffness kPa, controlled attenuation dB/m, valid measurements, IQR/median | Site eCRF with range checks |
| MRI fat fraction | Liver fat % by MRI-PDFF, central read date | Site eCRF entered from the imaging report |
| FIB-4 inputs | Age, AST, ALT, platelets | Lab table; FIB-4 entered as a value or computed from the export |
| Liver labs | ALT, AST, GGT, ALP, bilirubin, albumin, INR, platelets | Lab results with reference ranges and CS/NCS prompts |
| Glycaemic control | HbA1c, fasting glucose, diabetes medication changes | HbA1c log |
| Body composition | Weight, waist, BMI, optional DXA | Vital signs with BMI as a calculated field; DXA form |
| Lipids and blood pressure | LDL, triglycerides, systolic and diastolic BP | Lab table; MAP as a calculated field |
| Alcohol intake | Units per week, screening questionnaire | Screening form and visit check |
| Kidney function | Creatinine and eGFR | eGFR CKD-EPI 2021 as a calculated field |
FIB-4 is not one of Capture's built-in calculated fields. Enter it from the lab report or calculate it from the export; the same applies to histology endpoint status.
Non-invasive tests
Vibration-controlled transient elastography gives a liver stiffness measurement in kilopascals and, on many devices, a controlled attenuation parameter in dB/m as a marker of fat. Record the median value, the number of valid measurements, the interquartile range to median ratio if your imaging manual uses it as a quality criterion, the probe size and whether the participant was fasting. Without those fields, a stiffness change of 2 kPa between visits cannot be told apart from a change of probe. Range checks (range low, range high) raise an auto-query on impossible values, and per-field source data verification can be set on the endpoint values.
MRI proton density fat fraction (MRI-PDFF) is often a primary or key secondary endpoint in earlier-phase trials because it responds within weeks. It is read centrally; enter the whole-liver percentage and the read date from the report. Magnetic resonance elastography adds another stiffness value in kPa; keep it on its own field so it is never confused with ultrasound stiffness.
FIB-4 combines age, AST, ALT and platelet count (age multiplied by AST, divided by platelets multiplied by the square root of ALT), and commonly used cut-offs around 1.3 and 2.67 help with screening for advanced fibrosis. It is not one of Capture's built-in calculated fields. The usual approach is to collect the inputs in the lab table and calculate FIB-4 from the export, or to have the site enter the value from the lab report if the lab returns it. If you use FIB-4 to pre-screen before biopsy, put the decision on the screening form with a reason, so screen failures are traceable. The lab unit converter helps when sites report AST, ALT or platelets in different units.
Pre-screened
312
Biopsy done
128
Randomised
61
Open queries
14
Upload your protocol, let the AI study builder draft the forms, add a Sum score for the activity total and test it with a mock participant. Free sandbox, no credit card.
Liver safety and metabolic data
Standard drug-induced liver injury rules compare ALT and bilirubin with the upper limit of normal. In MASH many participants start above it, so many protocols define liver-safety triggers relative to the participant's own baseline as well, and require repeat testing within a set number of days. Build the liver panel as a lab table with analytes as rows and reference ranges by sex where needed: results outside the range are flagged, and the investigator must record whether each is clinically significant and, if so, link or create an adverse event before the form can be submitted. Multiples of baseline and the trigger logic itself are best calculated from the export or reviewed on a listing, because they depend on baseline definitions in the protocol.
Weight, waist circumference, HbA1c, lipids and blood pressure are both safety data and effect modifiers. A participant who loses 10% of body weight on a background drug can improve their liver regardless of the study treatment, which is why protocols require stable weight and stable doses of diabetes and weight-loss drugs before baseline. Record those drugs as dated concomitant medication rows, add a screening question for the date of the last dose change, and let BMI and mean arterial pressure come from Capture's calculated fields. If your trial combines liver endpoints with a weight-management drug, the data model on EDC for GLP-1 and weight management trials and EDC for diabetes trials covers the metabolic side, and EDC for metabolic studies the broader set. For participants with kidney disease as well, see EDC for chronic kidney disease trials.
Build sequence
The AI study builder drafts visits and forms; the form drafter turns the lab manual into a lab table with units and reference ranges. A person reviews everything.
One read form per reader with option scores and a Sum, a consensus form and a biopsy logistics form with a date-window check.
Elastography with quality fields and range checks, MRI fat fraction and any MR elastography.
Pathologist and imaging reader roles see only what they score; blinded roles never receive the arm.
A non-evaluable biopsy, a historical biopsy outside the window, an ALT rise from a high baseline; check the queries and the export.
Approved forms lock for live use. Real participants start the paid live phase.
Before first participant
Scoring system and version, number of readers, consensus rules, adequacy criteria.
Device type, probe rules, fasting, quality criteria for each stiffness or fat value.
FIB-4 or stiffness pre-screen thresholds and the biopsy window.
Triggers relative to baseline and ULN, repeat-test timing, stopping rules.
Diabetes and weight-loss drug stability windows checked at screening.
One row per read and per analyte; SDTM datasets checked with your programmers.
Both. MASH is the 2023 name for what was called NASH. Build your forms with the term your protocol uses; the data model is the same.
No. FIB-4 is not in the calculated-field list. Collect age, AST, ALT and platelets and compute it from the export, or enter the value from the lab report.
Yes. Each reader completes their own read form, and a separate consensus form records the agreed scores. Each record keeps its own audit trail.
Yes, as a Sum score built from the option scores of the component fields, calculated when the form is saved and included in the export. Endpoint status across visits is computed from the export.
No integration is claimed. Values are entered from the device printout or central read report, with range checks and per-field SDV.
Lab tables flag out-of-range results, and the investigator records clinical significance and links or creates an adverse event before submitting.
The sandbox is free with every feature and no credit card. You pay only when the study goes live; see the pricing page.
Keep exploring
EDC for GLP-1 and weight management
Weight, dose titration and GI tolerability.
EDC for diabetes trials