Use case · Aesthetic procedures and devicesUpdated November 26, 2026

Aesthetic clinical study software for clinics and med spas

An aesthetic study lives on standardised photos, an evaluator who does not know which side or which visit they are rating, and a subject's own view of the result. Capture records the treatment parameters, the blinded scores with their image IDs, the satisfaction and downtime diaries and the skin reactions in one audit-trailed study. Build it free.

  • Blinded evaluator scoring by image ID
  • Treatment parameters per session
  • Downtime and reaction diaries

Free sandbox · No credit card · 21 CFR Part 11 compliant

  • ISO 27001 certified
  • 21 CFR Part 11 compliant
  • GDPR compliant
  • EU and US data hosting
  • HIPAA compliant
  • ICH GCP E6(R3) compliant
Blinded evaluator rating (demo)
Image set 7731 · Evaluator 2 · Visit label hiddenDraft

Image set

Image set ID (from imaging system)

IMGID
IMG-7731-L

Image quality acceptable for rating

IMGQC
YesNo, re-take requested

Ratings

Severity grade on the study photo-numeric scale

PNSGRD

Reference images per grade in the rater manual

01234

Global aesthetic improvement versus paired baseline

GAIEVAL
Much improvedImprovedNo changeWorseMuch worse
Demo data only. Photos stay in the clinic imaging system; the eCRF holds the score and the image ID.Save
The evaluator role never receives the treatment arm or the treated side.

What an aesthetic clinical study needs from its data system

  • The primary endpoint is usually a blinded rating of photos: a trained evaluator grades standardised images on a photo-numeric severity scale without knowing the visit, the arm or the treated side.
  • Improvement is rated as well as severity: global aesthetic improvement scales (often five points from much improved to worse) are used by investigators, evaluators and subjects.
  • Treatment parameters are the dose: volume and depth for injectables, energy, passes and spot size for devices, needle depth and passes for microneedling. Record them per area, per session.
  • Downtime and skin reactions are expected: erythema, oedema, bruising and tenderness are typical; the diary separates expected reactions from adverse events by severity and duration.
  • Photos stay in the imaging system: Capture records the scores and the image IDs, not the images.

Study types

Injectables, energy-based devices and microneedling from a clinic

Aesthetic clinics and med spas run several kinds of studies: investigator-initiated studies of a technique, sponsor studies of a new filler, toxin or device run at a handful of clinics, split-face or split-body designs that compare two treatments on the same person, and post-market follow-up of a marketed product. The regulatory route depends on the product and the country; an injectable or a device used outside its cleared indication may need an investigational application, and this page does not state the status of any product. For the clinical investigation pathway see EDC for medical device clinical trials and the post-market studies page.

Microneedling studies (with or without radiofrequency or a topical) record needle depth by area, number of passes, endpoint reached (for example pinpoint bleeding or uniform erythema), any topical applied and the post-procedure care given. Energy-based devices (lasers, intense pulsed light, radiofrequency, ultrasound) record device settings, passes, cooling and the Fitzpatrick skin type, because skin type changes both settings and the risk of pigment change. Injectables record product lot, volume per injection point or area, depth, technique and touch-up sessions. In every case a repeating row per treated area keeps the parameters structured, and each row has its own audit trail.

Two neighbouring pages cover different studies. Cosmetic and skincare claims studies test topical products for marketing claims with consumer panels and instrumental readings. Dermatology clinical trials test treatments for skin disease with disease severity indices. This page is for procedures and devices delivered by a practitioner for an aesthetic outcome.

Which page fits

Aesthetic procedure studies versus cosmetic claims and dermatology trials

Aesthetic procedure study (this page)Cosmetic claims studyDermatology trial
InterventionInjectable, device or microneedling session by a practitionerTopical product used at homeDrug or device for a skin disease
Primary outcomeBlinded photo rating on a severity or improvement scalePanel perception and instrumental readingsDisease severity index and quality of life
Who ratesBlinded evaluator, investigator, subjectConsumer panellists and expert gradersInvestigator, often blinded
Key safety dataExpected treatment reactions, nodules, pigment changeIrritation and toleranceAdverse events by system and severity
Typical siteAesthetic clinic or med spaTesting laboratoryDermatology clinic or hospital

Blinded evaluation

Photo-numeric scales, improvement scales and the blinded evaluator

Validated photo-numeric scales describe severity of one feature (wrinkles in one area, volume loss, laxity, scarring) in grades, commonly four or five, each illustrated by reference photos. Responder definitions are often at least one grade of improvement from baseline, sometimes confirmed by two evaluators, but take the definition from your protocol. Many scales are published with conditions of use or are owned by a sponsor; the licence and the reference images stay with your study documents, and Capture does not supply them.

The evaluator works from standardised photographs taken with fixed lighting, distance and position in the clinic imaging system. Capture does not store photos. Instead, the coordinator records the image set ID at each visit, the photo set is randomised and anonymised in the imaging system, and the evaluator enters the grade against the image ID. Because the eCRF only shows the image ID, the evaluator sees neither visit nor side, and blinded roles never receive treatment-arm values, which Capture enforces in the database; see how blinding works. Use two evaluators where the protocol requires and record each separately; agreement is analysed from the export.

Improvement scales of the global aesthetic improvement type are usually rated by the investigator and the subject at follow-up visits and by the blinded evaluator on paired images. Record each rater on a separate form, because their views differ and reviewers compare them. Subject satisfaction and willingness to recommend can go to the subject's phone through a secure link with email reminders, so the answer is not given in front of the practitioner.

Build the treatment log, the evaluator form and the downtime diary

Enter a split-face mock subject, rate two image IDs as a blinded evaluator and export. Free sandbox, no credit card.

Build your aesthetic study free

Downtime and safety

Downtime diaries and expected skin reactions

Most procedures cause expected reactions: erythema, oedema, bruising, tenderness, itching, pinpoint bleeding after microneedling, crusting after some energy treatments. A short daily diary on the subject's phone for the first one to two weeks records each reaction as none, mild, moderate or severe, plus a question on whether the subject avoided normal activities, which gives a downtime measure. Keep the diary to under a minute; a long questionnaire on the day after treatment is not completed.

Decide in the protocol when an expected reaction becomes an adverse event: for example when it is severe, lasts longer than a set number of days or needs treatment. A rule on the diary can show staff an alert when a subject reports a severe reaction, so the clinic follows up, and the adverse event form records events such as nodules, infection, prolonged swelling, pigment change or vascular events with dates, severity, relationship and outcome. Concomitant skincare and procedures go on the concomitant medications form, because a retinoid or a peel between sessions can change the result.

Post-treatment downtime diary, day 2 (demo)

Subject 003-0019 · Microneedling session 1

Redness

DTERY
NoneMildModerateSevere

Swelling

DTOED
NoneMildModerateSevere

Bruising

DTBRU
NoneMildModerateSevere

Did you avoid usual activities today because of how your skin looked or felt?

DTAVOID
NoYes
Demo data only. A severe answer can alert named study roles.Save
Downtime is a diary field, not a guess at the next visit.

Build sequence

From aesthetic protocol to a running study

  1. 1

    Upload the protocol

    The AI study builder drafts visits and forms from a PDF, DOCX or DOC protocol; nothing is saved without review.

  2. 2

    Build the treatment log

    One row per treated area with product or device settings, depth, passes and lot.

  3. 3

    Build the rating forms

    Evaluator, investigator and subject forms, each with the image ID and the scale grades.

  4. 4

    Set randomisation and roles

    Arm or treated side assigned in Capture; the evaluator role never receives it.

  5. 5

    Add diaries and consent

    Downtime diary and satisfaction questionnaire on the phone; eConsent with email OTP.

  6. 6

    Test and go live

    Enter mock subjects, check the evaluator view and the export, then approve the forms.

Before the first subject

Aesthetic study readiness checklist

Photo standard written

Camera, lighting, distance, positions and who checks image quality.

Image ID scheme agreed

How the imaging system names and randomises image sets, and where the ID is entered.

Scales and licences filed

Photo-numeric and improvement scales, rater manual and terms in the study documents.

Evaluators trained

Training set rated before go-live, with agreement reviewed.

Reaction rules defined

When an expected reaction becomes an adverse event.

Treatment parameters fixed

Which settings are recorded per area and which are protocol limits for range checks.

FAQ

Questions teams ask before they switch

Something not covered here? Ask us directly.

Can we upload before-and-after photos to Capture?

Photos stay in your clinic imaging system. The eCRF records the image set ID, image quality and the evaluator scores, so the scores are linked to the images without storing them in Capture.

How does the evaluator stay blind?

The evaluator rates by image ID, without visit or side, and blinded roles never receive treatment-arm values, enforced in the database. Test the evaluator view in the sandbox.

Does this work for microneedling studies?

Yes. A row per treated area records needle depth, passes, endpoint, any topical and aftercare, and the downtime diary captures redness and swelling day by day.

Can we run a split-face design?

Yes. Randomise the side in Capture, record parameters per side and rate each side by its own image ID.

Can we use a published photo-numeric scale?

Yes, under its terms. Capture records the grades; the scale, reference images and licence stay with your study documents.

How is this different from a cosmetic claims study?

Claims studies test home-use topical products with consumer panels and instruments. Aesthetic procedure studies test practitioner-delivered treatments with blinded photo ratings.

What does it cost?

Building and testing is free in the sandbox with every feature and no credit card. You pay when the study goes live; see pricing.

Start your aesthetic study free

Free sandbox with every feature. No credit card.

Build your aesthetic study free