A good query names the field, the problem and the action the site must take, in one or two sentences. This guide shows 15 weak queries rewritten, by type, and how edit checks send many of them for you.
Free sandbox · No credit card · 21 CFR Part 11 compliant
Heart rate
HRAuto-query: outside range 30-200. Confirm the value against source.
Systolic blood pressure
SYSBPWithin range
Reason for change
REASONRequired when the value is corrected
What makes a query good
Anatomy
Queries are the main channel between data management, monitors and sites. They are read by a busy coordinator between participant visits, often on a phone, often without the protocol to hand. Everything the coordinator needs to answer correctly has to be inside the text or visible next to the field.
A reliable structure has five parts. Whether you write them as separate lines or one sentence matters less than including all of them.
Participant, visit and field. In an EDC the query sits on the field, so the text can skip the location, but exports and emails need it.
The value as entered and the other value, rule or record it conflicts with. State both numbers or dates.
Only if not obvious: "protocol range for entry is 30 to 200" or "window is Day 28 +/- 3". One clause is enough.
Confirm, correct, or explain. Offer the legitimate options, including "value is correct as entered, please confirm against source".
No blame, no suggested answer, no "should be". The site decides from source.
Examples
Participant IDs and values are invented for illustration. Adapt the thresholds to your protocol.
| Type | Weak query | Strong query |
|---|---|---|
| 1. Missing value | Missing data. | Visit 3 diastolic BP is blank while systolic is 128 mmHg. Please enter the value or mark the measurement as not done with a reason. |
| 2. Out of range | Value wrong? | Heart rate is 20 bpm at Visit 2. The entry range is 30 to 200 bpm. Please confirm against source and correct if needed. |
| 3. Inconsistent fields | Check sex. | Sex is Male on Demographics and a positive pregnancy test is recorded at Screening. Please confirm which is correct. |
| 4. Date logic (AE) | Dates look off. | AE "Nausea" ends 03 Mar 2026 but starts 07 Mar 2026. Please check both dates against source. |
| 5. Date logic (visit window) | Late visit. | Visit 4 was done on Day 41. The window is Day 28 +/- 3. Please confirm the visit date, or record a protocol deviation if the date is correct. |
| 6. Unit | Weight is wrong. | Weight is 172 with unit kg. The Visit 1 weight was 71 kg. Please confirm the unit of measure. |
| 7. AE and concomitant medication | CM and AE mismatch. | Ondansetron is recorded as a concomitant medication for nausea from 12 Mar but no nausea adverse event is entered. Please add the adverse event or correct the indication. |
| 8. AE action taken | Update AE. | AE "Headache" has action taken "medication given" but no matching concomitant medication. Please add the medication or change the action. |
| 9. Duplicate record | Duplicate. | Two adverse events "Nausea" both start 02 Apr 2026 with the same severity. Please confirm these are separate events or delete one with a reason. |
| 10. Eligibility | Not eligible? | Inclusion criterion 1 (age 18 to 65) is answered Yes, but date of birth gives age 71 at consent. Please confirm the birth date and the answer. |
| 11. Lab significance | Lab abnormal. | ALT is 412 U/L, above the reference range, with no clinical significance assessment. Please enter the investigator assessment. |
| 12. Consent sequence | Check consent date. | Consent date is 06 May 2026 but screening bloods are dated 05 May 2026. Please confirm both dates against source. |
| 13. Calculated value | BMI incorrect. | Height 178 cm and weight 98 kg give BMI 30.9. A value of 27 is entered in the free-text note. Please correct the note or the measurement. |
| 14. Serious AE | SAE needs form. | AE "Hospitalisation for pneumonia" is marked serious but no SAE form exists. Please complete the SAE form or change seriousness. |
| 15. Dosing | Wrong dose. | Dose given is 400 mg. The assigned dose at randomisation is 200 mg. Please confirm the dose given and explain any difference. |
Every strong query states the value, the conflict, and the action. None tells the site what the right answer is.
Workflow
The site answers a query: it confirms the data are right as entered, or corrects them in the eCRF with a reason, or explains why the value cannot be known. The person who raised the query, or the data manager, closes it only after checking the answer resolves the question. A query that is answered but not closed stays in the review queue so nothing is lost.
No single turnaround number applies across trials, and published figures vary by sponsor, therapeutic area and phase, so this page does not quote one. Set targets in the data management plan for time to site response and time to closure, assign someone to chase overdue queries each week, and track the open count by site. Persistent late responses at one site are a monitoring signal, not just a data cleaning nuisance. For the wider process see the clinical data cleaning guide.
Open (raised, awaiting the site), answered (site has responded), closed (reviewer accepts), and re-opened (the answer did not resolve the question). A good query list shows each state and filters by site, form and priority.
Do not query things the audit trail already explains, cosmetic spelling, or anything the protocol allows. Excess queries slow sites and hide the ones that matter.
In the free sandbox, set a range edit check on a field, enter a bad value, and watch the auto-query appear on the form. No credit card, no time limit, pay only at go-live.
Manual vs auto
A manual query is raised by a person after reading the data. It is right for cross-form judgement: an AE with no matching medication, a lab without an assessment, an eligibility answer that contradicts a date of birth. These need context a rule cannot encode cheaply.
An auto-query is raised by the system when a value breaks a rule defined in the form. Capture supports edit checks with range high, range low and custom value rules and a configurable priority, and the query is created automatically when a site enters a breaking value. The site sees it immediately, while the participant may still be in clinic and the source can be checked at once. That immediacy is the main saving: an error fixed in the minute it is made is cheaper than one found three weeks later.
A sensible split is to automate everything that a rule can state as a single condition (missing required values, range limits, impossible dates) and keep people for the queries in this guide numbered 3, 7, 8, 9, 10, 11 and 14 that span forms. Review the auto-query volume after the first participants: a rule that fires on a third of entries is too tight or the form wording is unclear, and fixing the form is better than answering the same query repeatedly. See also query management software for clinical trials.
In Capture
Define a range or value rule on a field, choose a priority, and Capture raises an auto-query as soon as a site enters a value that breaks it. The query list shows open, answered and closed queries with category and priority.
Edit checks / auto-queries
2Type
Range High
Operator
Greater than
Value
180
Priority: High
Type
Range Low
Operator
Less than
Value
80
Priority: Normal
Query raised automatically
Value 192 violates limit (180). Please verify.
In Capture
Monitors and data managers work from a single list that shows state and priority. Filter to what is overdue or high priority and send a manual query where judgement is needed.

Before you send
Both numbers or dates are in the text.
Says what it conflicts with: a range, a window, another field, a record.
Confirm, correct or explain. Includes the option that the value is right.
No "should be", no suggested value, no blame.
Split compound queries so each can be closed independently.
Not already explained by a note, the audit trail or a protocol allowance.
Safety and endpoint queries first; cosmetic last.
The field and value, what it conflicts with, and the action the site should take, in neutral wording. For example: "Heart rate is 20 bpm at Visit 2. The entry range is 30 to 200 bpm. Please confirm against source and correct if needed."
It should not. Leading queries risk the site changing data to fit the suggestion rather than the source. Ask the site to confirm or correct from source, and let them state the value. Your sponsor SOP may add its own rules on query wording.
A manual query is raised by a person after reviewing data, and an auto-query is raised by a rule when a value is entered. In Capture, edit checks (range high, range low and custom value rules with a priority) raise auto-queries automatically. See edit checks software.
There is no universal figure to cite. Set a response and closure target in your data management plan, review overdue queries weekly, and treat consistently late responses at one site as a monitoring signal.
The reviewer who raised it, or the data manager, closes it after checking the site answer actually resolves the question. If it does not, re-open it with a clarifying note rather than raising a new query.
State both records and ask for an action: "Ondansetron is recorded for nausea from 12 Mar but no nausea adverse event is entered. Please add the adverse event or correct the indication." See adverse event for definitions.
No fixed rate applies, but a rule that fires on a large share of entries usually signals a badly set range or a confusing form. Review auto-query volume after the first participants and adjust the rule or form wording. See query management software for tracking.
Keep exploring
Build a form free, set an edit check, and see the auto-query on the field. No credit card; pay only when you go live.