Free tool · Planning · Fixed sample sizeUpdated November 1, 2026

Minimum detectable effect calculator: what can your trial actually detect?

The sample size is capped by budget, a rare disease or a recruitment ceiling. Enter the number you can enrol and get the smallest mean difference, response rate or hazard ratio that trial can detect at your power, for two means, two proportions and time-to-event outcomes.

  • Means, proportions and hazard ratios
  • Dropout built in
  • Runs in your browser

Free sandbox · No credit card · 21 CFR Part 11 compliant

  • ISO 27001 certified
  • 21 CFR Part 11 compliant
  • GDPR compliant
  • EU and US data hosting
  • HIPAA compliant
  • ICH GCP E6(R3) compliant
Demo: 60 per arm, 10% dropout, SD 12, alpha 0.05, 80% power

Evaluable per arm

54

Detectable difference

6.5

Standardised d

0.54

Difference detectable at 70% power5.8/8

5.8

Difference detectable at 80% power6.5/8

6.5

Difference detectable at 90% power7.6/8

7.6

Demo data. A real effect smaller than 6.5 units is more likely than not to be missed.

Minimum detectable effect in brief

  • The minimum detectable effect (MDE) is the smallest true effect your trial has the chosen power to detect, given the sample size you can actually enrol. It is the sample size calculation run backwards: n is fixed, the effect is the unknown.
  • It is a property of the design, not of the data. You compute it before the trial from n, the variability, alpha and power. Computing “observed power” from a finished trial’s result adds nothing and misleads.
  • Halving the MDE costs four times the participants. The effect you can detect shrinks with the square root of n, so the last few participants buy very little.
  • Compare the MDE with the effect you believe in. If the MDE is larger than the clinically important difference, or larger than the effect seen in earlier work, the trial is underpowered for its own question.
  • Dropout comes first. Only evaluable participants count, so the tool converts the number you randomise into the number you analyse before it solves for the effect.

Free tool

Solve for the effect you can detect

The defaults show a two-arm trial with 60 participants per arm, 10% dropout, SD 12 and 80% power. Switch the outcome type, change the numbers and read the plain-language result and the power table underneath.

Primary outcome
%
Small-sample t correction
Smallest detectable difference
6.53
standardised d = 0.54

With 54 and 54 evaluable participants and σ = 12, the trial has 80% power only for a true difference of 6.53 or larger. A smaller real effect is more likely than not to be missed.

Minimum detectable effect at other power levels
PowerDifference
70%5.79
80%6.53
90%7.56

Planning aid, not validated software; runs in your browser and stores nothing. Two arms, a two-sided test and the standard normal approximations (means: optional t correction on n₁ + n₂ − 2 degrees of freedom; proportions: pooled-variance formula; survival: Schoenfeld with proportional hazards). It is the inverse of the sample size calculators: it fixes n and solves for the effect. Confirm the final figures with a statistician.

When you need it

Why a fixed sample size turns the question around

The usual sample size question starts from an effect and asks for a number. In practice the number often arrives first. A rare disease has 80 eligible patients in the country. A grant funds 120 participants. A phase 2 study is budgeted for one cohort. A site network can recruit about 30 per arm in the window the sponsor will wait. In each case the useful question is not “how many do we need?” but “what difference could we reliably see with the people we can get?” The answer is the minimum detectable effect.

Stating the MDE in the protocol is good practice for two reasons. It lets the reader judge whether the trial is worth running before anyone is enrolled, and it removes the temptation to claim after the fact that a null result “proves no effect”. A trial with an MDE of 6.5 mmHg that finds 3 mmHg has not shown the drug does nothing; it has shown that any effect is probably smaller than 6.5. The power analysis calculator gives the power at one effect; this tool gives the effect at one power, for three outcome types.

The MDE is also the right language for a feasibility conversation with a funder or an ethics committee. It turns “we can only recruit 60 per arm” into “with 60 per arm and the SD from the pilot, we can detect a difference of 6.5 points, which is 0.54 standard deviations, and the smallest difference we would call clinically important is 5”. That sentence makes the trade-off visible, and it is easier to defend than a sample size that was simply the budget.

Method

How the minimum detectable effect is calculated

All three formulas are the standard sample size formulas solved for the effect. Let z_a be the normal quantile for the two-sided alpha (1.96 at 0.05) and z_b the quantile for power (0.84 at 80%).

Two means. The detectable difference is (z_a + z_b) × SD × √(1/n₁ + 1/n₂), using the number evaluable in each arm. With 64 per arm and an SD of 1 this gives 0.495, the textbook “64 per group for a half-SD effect at 80% power”. The tool optionally replaces the normal quantiles with t quantiles on n₁ + n₂ − 2 degrees of freedom, which matters below about 30 per arm. In the default example, 60 randomised per arm and 10% dropout leave 54 evaluable; with SD 12 the MDE is 6.53 (6.47 with the plain normal formula), a standardised difference of 0.54.

Two proportions. There is no closed form for the detectable proportion, because the variance depends on the proportion itself, so the tool solves the pooled-variance sample size formula for the treatment-arm proportion by bisection. With a 30% baseline and 93 per arm it returns 50.0% on the high side, which agrees with the two-proportions sample size calculator (93 per arm for 30% against 50%). On the low side it returns 13.2%: a fall of 16.8 points is detectable where a rise of 20.0 points is needed. The asymmetry is real, so state the direction of your hypothesis.

Time to event. Under proportional hazards, the number of events D needed to detect a hazard ratio HR with allocation fraction p to the treatment arm is D = (z_a + z_b)² / (p(1 − p) (ln HR)²) (Schoenfeld, 1981). Inverted, HR = exp(−(z_a + z_b) / √(D p(1 − p))). With 247 events, 1:1 allocation and 80% power the detectable hazard ratio is 0.700, the same pairing the survival sample size calculator uses in the forward direction. The participant count only enters through the proportion who have an event.

These are planning approximations. They assume a two-sided test, a single final analysis, independent observations and, for survival, proportional hazards and independent censoring. Interim looks change the maximum sample size (see the group sequential design calculator); clustered or repeated data change the variance. The glossary entry on sample size calculation lists the other inputs a protocol must state.

Worked examples

Six fixed-n scenarios and what they can detect

All at two-sided alpha 0.05 and 80% power, 1:1 allocation, computed with this tool’s formulas. Evaluable numbers are after dropout.

ScenarioEvaluableVariabilityMinimum detectable effectHow to read it
Systolic blood pressure, mean change54 per arm (60 randomised)SD 12 mmHg6.5 mmHg (d = 0.54)Worthwhile only if 6.5 mmHg is a plausible drug effect
Same trial, fewer participants30 per armSD 12 mmHg8.8 mmHg (d = 0.73)Only a large effect is visible; a modest one will usually be missed
Same trial, doubled200 per armSD 12 mmHg3.4 mmHg (d = 0.28)Four times the participants of 54-per-arm buys about half the MDE
Responder rate, baseline 30%93 per armBinomial50.0% (up) or 13.2% (down)Detects +20 points or −17 points
Responder rate, baseline 30%, small study45 per arm (50 randomised)Binomial59.0% (up) or 7.3% (down)Needs a +29 point effect: unrealistic for most drugs
Oncology-style progression, 1:1247 eventsProportional hazardsHR 0.700A 30% hazard reduction; with 100 events only HR 0.571

Hazard ratios for other event counts at 80% power, 1:1: 100 events, HR 0.571; 150 events, HR 0.633; 300 events at 90% power, HR 0.688. Check each against your own statistician’s software before it goes in a protocol.

Interpretation

Is the MDE good enough? Four comparisons that decide it

A number is only useful against a yardstick. Compare the MDE with four things, in this order.

1. The minimal clinically important difference

If the smallest difference that would change practice is 5 points and the MDE is 6.5, the trial can miss a worthwhile benefit. Either enlarge it, tighten the measurement, or accept in writing that the study is a signal-finding step. Defining the endpoint and its important difference comes first; the primary endpoint glossary entry covers what to specify.

2. The effect in earlier evidence

Phase 2 effects are usually optimistic. If the earlier study reported a 7-point difference, planning to detect exactly 7 leaves no room for shrinkage; planning to detect 5 is more robust.

3. The variability assumption

An MDE is proportional to the SD. A 25% underestimate of the SD makes the real MDE 25% larger. Run the tool at an SD you consider pessimistic and see whether the answer still holds; the two-means sample size calculator discusses where the SD should come from.

4. The evaluable number, not the randomised number

Dropout, missing primary assessments and protocol exclusions reduce n. Use the realistic loss rate; the dropout-adjusted sample size calculator explains why dividing is correct and adding a percentage is not. An MDE computed on the randomised number is optimistic.

Turn a fixed sample size into a study you can run

Build the eCRFs, visit schedule and randomization for your capped cohort in the free sandbox, with no credit card. Pay only when you go live.

Plan your study free

The square-root rule

How the detectable difference shrinks as n grows

SD 12, two-sided alpha 0.05, 80% power, t correction on, equal evaluable numbers per arm.

Evaluable per armMinimum detectable differenceStandardised dRelative to 54 per arm
308.80.73135%
546.50.54100%
1004.80.4073%
2003.40.2852%

Going from 54 to 200 per arm is 3.7 times the participants for roughly half the MDE. If the budget can stretch only a little, spend it on lowering the SD (a better measurement, a baseline covariate, repeated measures) as often as on n.

In Capture

Keep the assumptions behind the MDE honest while the study runs

An MDE is only as good as the SD and the dropout you assumed. Capture does not calculate sample sizes; it keeps the data that tests your assumptions clean and visible, and puts randomization in the same system as the forms.

  • Edit checks raise auto-queries when a value breaks a range rule, which protects the variability you planned around.
  • Visit schedules with windows that flag late visits, so primary assessments are not lost to timing.
  • A status overview of enrolment and completion to compare against the evaluable number you planned.
  • Randomization in the same platform as the eCRFs, with every allocation in the audit trail.
Browse the clinical trial software features
Status overview · subjects by visit
SCRD1W2W4W8W12EOS
01-001
01-002
01-003
01-004
01-005
01-006
Complete Partial Missing Overdue Not done Screen-failed

For the protocol

What to write down next to the MDE

Outcome, scale and direction

Name the primary endpoint, its unit and whether a higher or lower value is better, so the one-sided or two-sided choice is clear.

Variability source

Cite the study or pilot the SD or baseline rate came from, and the number of participants behind it.

Evaluable versus randomised

State the dropout assumption and give both numbers.

Alpha, power and test

Two-sided 0.05 and 80% or 90% are common; say which you used.

The clinical yardstick

Give the minimal clinically important difference next to the MDE so readers can compare them.

What the result will and will not show

A non-significant result rules out effects larger than about the MDE, not all effects.

FAQ

Questions teams ask before they switch

Something not covered here? Ask us directly.

What is the minimum detectable effect?

It is the smallest true effect (a mean difference, a difference in proportions or a hazard ratio) that a trial with a given sample size has the chosen power to detect at the chosen significance level. It is computed before the trial from n, the variability, alpha and power.

How is the minimum detectable effect different from the effect size in a sample size calculation?

They are the same relationship used in opposite directions. A sample size calculation fixes the effect and solves for n. The minimum detectable effect fixes n and solves for the effect. If you plug the MDE back into a sample size calculation with the same alpha, power and variability, you get the n you started with.

Is the minimum detectable effect the same as the minimal clinically important difference?

No. The MDE comes from statistics and your sample size; the minimal clinically important difference comes from clinical judgement about what matters to patients. A well-planned trial has an MDE at or below the clinically important difference. If the MDE is larger, the trial can miss a difference that matters.

Why does the detectable proportion differ above and below the baseline?

The variance of a proportion is p(1 − p), which is not symmetric around the baseline. Moving up from 30% adds variance, moving down toward 0% removes it, so a smaller absolute change is detectable on the low side. With a 30% baseline and 93 per arm, the high side is 50.0% (+20 points) and the low side 13.2% (−16.8 points).

How many events do I need for a given hazard ratio, and how many patients does that mean?

Events come from the Schoenfeld formula: for a hazard ratio of 0.70 with 1:1 allocation, 80% power and two-sided alpha 0.05 about 247 events. Participants then depend on the proportion expected to have an event during follow-up: divide events by that proportion. The survival sample size calculator works forward from the hazard ratio.

Should I use the t correction?

For means with fewer than about 30 evaluable participants per arm, yes: the t quantiles are larger than the normal ones and the MDE is a little larger. With 54 per arm the difference is small (6.53 against 6.47 in the default example). The correction is exact in form for means and an approximation for the other two outcome types, where the tool uses the normal formulas.

Can I use this for a non-inferiority or equivalence trial?

Not directly. Those designs have a margin instead of an effect, and one-sided or two one-sided tests. See the non-inferiority sample size calculator and the equivalence calculator, and treat the margin as the quantity you can demonstrate.

Is anything stored or sent?

No. The calculation runs in your browser and nothing is saved or transmitted. It is a planning aid, not validated software, and a statistician should confirm the final design.

Know what you can detect, then build the study

Build the eCRFs, visit schedule and randomization in the free sandbox with nearly every feature. No credit card, pay only at go-live.

Plan your study free