Free tool · Compliance referenceUpdated November 1, 2026

21 CFR Part 11 and Annex 11 readiness assessment for the tool you use today

Answer 25 questions about your current system or process. Each is tagged to the 21 CFR Part 11 subpart and the EU GMP Annex 11 clause it comes from. You get a score by area and a printable list of gaps.

  • 25 questions, 6 areas
  • Tagged to Part 11 and Annex 11
  • Printable gap report
  • Nothing stored

Free sandbox · No credit card · 21 CFR Part 11 compliant

  • ISO 27001 certified
  • 21 CFR Part 11 compliant
  • GDPR compliant
  • EU and US data hosting
  • HIPAA compliant
  • ICH GCP E6(R3) compliant
Demo gap report · spreadsheet-based process

Overall

40%

Weakest area

Audit trail 20%

Gaps

21 of 25

  • Audit trail records old value, new value, reason11.10(e) · Annex 11 s9
  • Signature linked to record, cannot be copied11.70 · Annex 11 s14
  • Role-based permissions11.10(g)
  • Unique user IDs, no shared accounts11.10(d) · Annex 11 s12.1
  • Backups taken and restore testedAnnex 11 s7.2
Demo answers for an Excel-and-shared-drive process. Not a real assessment.

Part 11 and Annex 11 readiness in brief

  • 21 CFR Part 11 sets the FDA’s criteria for treating electronic records and electronic signatures as equivalent to paper. EU GMP Annex 11 covers computerised systems used in GMP-regulated activities. Clinical trial teams meet both through sponsors, inspectors and vendor questionnaires, and the two overlap heavily on audit trails, signatures, access control, validation and data retention.
  • The assessment below scores your current tool or process, whether that is a spreadsheet, a survey tool or an EDC. It does not score a vendor’s marketing.
  • The most common failures are not exotic: no independent audit trail, shared logins, signatures that are not linked to the record, and no evidence that anything was validated or that a backup can be restored.
  • The score is a prompt for a conversation, not a compliance determination. Equal weights, self-reported answers, no evidence review.
  • The revised Annex 11 was out for consultation in 2025. Check the current status before building a programme on either text; the controls below stay relevant under both.

Free tool

Score your current system or process

Pick one answer per question: Yes, Partly, No or N/A. Use Fill an example to see a typical spreadsheet-based process. Print or save the report as PDF when you are done. Nothing is saved or sent.

Runs in your browser. Your answers are not saved or sent anywhere. This is a self-assessment, not an audit or a compliance determination.

Audit trail and time
  • Does the system automatically record, with a timestamp, every action that creates, changes or deletes a record?

    Computer-generated, not typed by the user.

    21 CFR 11.10(e)Annex 11 s9, s12.4

  • Does each audit entry show who, when, the old value, the new value and (for changes) the reason?

    Check a sample record, not the vendor brochure.

    21 CFR 11.10(e)Annex 11 s9

  • Is the audit trail protected from editing, switching off or deletion, including by administrators?

    Previously recorded information must not be obscured.

    21 CFR 11.10(e)Annex 11 s9

  • Can you view and export the audit trail in readable form, and is it reviewed on a schedule?

    Review is a procedure, not a feature.

    21 CFR 11.10(b), 11.10(e)Annex 11 s9

  • Are system clocks controlled (time source, time zone) so audit timestamps are unambiguous?

    Neither text names a time-sync rule; this is good practice that supports time-stamped trails.

    21 CFR 11.10(e) (supporting)Annex 11 s9 (supporting)

Electronic signatures
  • Does every signed record show the signer’s printed name, the date and time, and the meaning of the signature (for example review, approval, authorship)?

    All three must appear in the readable record.

    21 CFR 11.50(a), 11.50(b)Annex 11 s14

  • Is each signature permanently linked to its record so it cannot be removed, copied or transferred to falsify a record?

    A pasted image of a signature does not meet this.

    21 CFR 11.70Annex 11 s14

  • Is each electronic signature unique to one person and never reused or reassigned?

    No shared or generic signing accounts.

    21 CFR 11.100(a)Annex 11 s14

  • Do non-biometric signatures use two distinct identification components (for example user ID and password) when signing?

    Different rules apply for the first signing in a session and later ones.

    21 CFR 11.200(a)Annex 11 s14

  • Is identity verified before an e-signature is issued, and do written policies hold people accountable for actions under their signature?

    Includes the certification to FDA described in 11.100(c) where it applies.

    21 CFR 11.100(b), 11.100(c), 11.10(j)Annex 11 s14

Access control and security
  • Is access limited to authorised people, each with their own user ID and no shared accounts?

    Joiner, mover and leaver steps count.

    21 CFR 11.10(d), 11.300(a)Annex 11 s12.1

  • Do role-based permissions limit who may enter, change, sign, approve and export?

    Check that roles are least-privilege.

    21 CFR 11.10(g)Annex 11 s12.1, s12.3

  • Are passwords or ID codes controlled: periodic revision, lockout after repeated failures, and prompt deauthorisation of lost or compromised credentials?

    Also covers transaction safeguards against unauthorised use.

    21 CFR 11.300(b), 11.300(c), 11.300(d)Annex 11 s12

  • Does the system enforce the order of steps where order matters (for example no approval before entry is complete)?

    Operational system checks.

    21 CFR 11.10(f)Annex 11 s5, s6

Validation, change control and suppliers
  • Has the system been validated to show accuracy, reliability, consistent performance and the ability to detect invalid or altered records?

    Evidence on file, scaled to risk.

    21 CFR 11.10(a)Annex 11 s4

  • Are user requirements and a risk-based validation scope documented, with the validation records retained?

    The risk assessment decides the depth.

    21 CFR 11.10(a)Annex 11 s1, s4.1, s4.4

  • Are changes to the system and its configuration documented, assessed, approved and re-tested as needed before use?

    Include configuration changes, not just software releases.

    21 CFR 11.10(k)(2)Annex 11 s10

  • Is the validated state re-confirmed through a periodic evaluation?

    For example an annual review of incidents and changes.

    21 CFR 11.10(a) (supporting)Annex 11 s11

  • For hosted or vendor-supplied software, is there a written agreement, a supplier assessment or audit, and clear responsibilities?

    The sponsor stays responsible for the data.

    21 CFR 11.10(a) (supporting)Annex 11 s3

Backup, retention and export
  • Are backups taken regularly and is the ability to restore them actually tested?

    A backup that was never restored is unproven.

    21 CFR 11.10(c)Annex 11 s7.2

  • Are records protected, readable and retrievable for the whole retention period, including after the system is retired?

    Plan format and access for archived data.

    21 CFR 11.10(c)Annex 11 s7.1, s17

  • Can you produce accurate, complete copies of records (with their audit trail and metadata) in readable and electronic form for inspectors?

    Try it before an inspection.

    21 CFR 11.10(b)Annex 11 s8.1

  • Are there procedures for incidents (including data integrity events) and for continuing work during a system outage?

    Written and rehearsed.

    21 CFR 11.10(a) (supporting)Annex 11 s13, s16

People and procedures
  • Are users, administrators and support staff trained and qualified for their roles, with training records kept?

    Training on the system and on the SOPs.

    21 CFR 11.10(i)Annex 11 s2

  • Are SOPs for operating and maintaining the system under revision control, with access limited to those who need them?

    Controls over system documentation.

    21 CFR 11.10(k)(1), 11.10(k)(2)Annex 11 s10 (supporting)

Overall readiness score
–
Answer at least one question · 0 of 25 questions scored
  • Audit trail and timenot scored
  • Electronic signaturesnot scored
  • Access control and securitynot scored
  • Validation, change control and suppliersnot scored
  • Backup, retention and exportnot scored
  • People and proceduresnot scored

Scoring: Yes = 2, Partly = 1, No = 0; N/A questions are left out. Bands: 85% or more few visible gaps, 60 to 84% gaps to close, under 60% significant gaps. Equal weights, so treat the score as a prompt for discussion. Clause references are to the 2011 Annex 11 text and the current 21 CFR Part 11; check them against the official text.

How the score works

From 25 answers to a gap report

Each question scores 2 for Yes, 1 for Partly and 0 for No. N/A questions drop out of both the points and the maximum, so a system with no signatures does not lose marks for signature controls. An area score is points divided by the maximum for the questions answered in that area, rounded to a whole percent, and the overall score is the same calculation across all areas. Bands are 85% or more (few visible gaps), 60 to 84% (gaps to close) and under 60% (significant gaps). Every question has the same weight, which is a simplification: a missing audit trail matters far more than an undocumented training record, so read the gap list in order and not just the percentage.

Worked example. The built-in example describes a team running a trial from spreadsheets on a shared drive. It answers Yes to 4 questions, Partly to 12 and No to 9, which is 21 gaps. The audit area scores 2 of 10 points (20%), signatures 5 of 10 (50%), access 4 of 8 (50%), validation and suppliers 2 of 10 (20%), backup, retention and export 4 of 8 (50%) and people and procedures 3 of 4 (75%). Overall that is 20 of 50 points: 40%, significant gaps. The two lowest areas, audit trail and validation, are the ones a spreadsheet cannot fix by procedure alone, because version history in a shared drive does not record the reason for a change or protect itself from edit.

The exact same calculation drives the printable report, so a quality manager can check the arithmetic by hand from the answers.

What “Partly” should mean

Use Partly when a control exists but you cannot prove it works every time or it covers only some records. “We have a procedure but have never checked that people follow it” is Partly. “The audit trail exists but administrators can switch it off” is Partly. If you have to explain why an answer is Yes, it is probably Partly, because an inspector will ask for the same explanation and the evidence behind it.

Where the questions come from

The audit, signature, access and records questions follow the headings of 21 CFR 11.10 (controls for closed systems), 11.50 and 11.70 (signature manifestation and linking), 11.100 to 11.300 (signature and identification code controls) and the matching clauses of the 2011 Annex 11 (audit trails in clause 9, electronic signature in 14, data storage and backup in 7, security in 12). Clocks and periodic evaluation are marked “supporting” because neither text sets a rule for them by name. Check every reference against the current official text before you quote it in a procedure.

Requirement map

Where each area sits in Part 11 and Annex 11

The two texts organise the same ideas differently. This map is a reading aid, not a legal cross-walk.

Area21 CFR Part 11EU GMP Annex 11 (2011 text)Typical evidence
Audit trail and time11.10(e); 11.10(b) for copiesClause 9; 12.4 (record who entered, changed or deleted)Sample record history, export of the trail, review log
Electronic signatures11.50, 11.70, 11.100, 11.200Clause 14Signed record showing name, date and time, meaning; signing procedure
Access control and security11.10(d), (f), (g); 11.300Clause 12; clause 2 for rolesUser list, role matrix, password policy, leaver checks
Validation, change control, suppliers11.10(a), (k)(2)Clauses 1, 3, 4, 10, 11Risk assessment, requirements, test records, change log, supplier assessment
Backup, retention, export11.10(b), (c)Clauses 7, 8, 16, 17; 13 for incidentsBackup schedule, restore test record, retention plan, inspector export
People and procedures11.10(i), (j), (k)(1)Clause 2Training records, SOP list with versions

Annex 11 is part of the EU GMP guide for medicinal products. Trial teams usually read it alongside GCP and regulator guidance on computerised systems in clinical trials rather than as a direct requirement on a trial database. Confirm with your quality or regulatory lead which texts apply to you.

Test the controls instead of reading about them

In the free sandbox you can enter sample data, change a value with a reason, sign, and open the audit trail. No credit card, and you pay only when you go live with real participants.

See Part 11 controls in the free sandbox

Closing the gaps

What to fix first, and what a spreadsheet cannot give you

Start with the questions that cannot be solved by writing a procedure. A computer-generated, time-stamped audit trail (21 CFR 11.10(e), Annex 11 clause 9) must record the date and time of entries and actions that create, change or delete records, must not obscure earlier values, and must be kept as long as the records. Version history in a shared drive or a spreadsheet’s track-changes can be switched off or edited by whoever has write access, so it rarely meets that bar. The same logic applies to signatures linked to records (11.70): a typed name or pasted image in a cell is not linked to the content it approves. See the Part 11 compliance checklist for the descriptive version and Annex 11 versus 21 CFR Part 11 for how the two texts differ.

Next, fix access. Unique user IDs and no shared accounts are cheap to implement and are the foundation for everything else: an audit trail that says “study team” is not an audit trail. Then close the evidence gaps, which cost time rather than money: a written risk assessment and requirements, test records, a change log, a supplier assessment for any hosted tool, a restore test of the backups and a training record for every user. The computer system validation page explains how much validation is proportionate, and the ALCOA+ data integrity checklist is a good companion for the record-level questions.

If you are choosing a replacement, read the questions as a requirements list for the vendor, and ask for the evidence behind each one. Capture’s own position is stated on the security page: it carries the 21 CFR Part 11 compliant badge with a validation package available on request, and validated use remains a shared responsibility between the vendor and the sponsor. The same logic applies when you compare Part 11 compliant EDC systems, Annex 11 compliant EDC or work through the 21 CFR Part 11 compliance checklist: the answer depends on the configuration, the validation evidence and your procedures, not on the product name.

In Capture

What the controls look like in a working system

Capture is built for trials, so the controls you just scored are features, not procedures. Use the sandbox to see each one with sample data before you decide whether it answers your gaps.

  • Field-level audit trail on every record: timestamp, user identity, old value, new value and reason for change, appended by the database and not editable through the interface; repeating rows have their own trail.
  • Electronic signatures with password re-authentication and a meaning statement, cryptographically linked to the exact document content at signing time.
  • Role-based access with PII segregation and row-level security at the database layer.
  • 21 CFR Part 11 compliant, with a validation package available on request. Sponsor validation of the use of the system remains a shared responsibility.
Audit trail entry · demo data

Field

Systolic BP

Old value

142

New value

124

Reason

Transcription error

Demo record. Who and when are captured on every change.

Before you rely on the score

Four checks on your own answers

Evidence sampled

For every Yes, open one real record or document that proves it. Anything you cannot show becomes Partly.

Two people answered

Have the system owner and the quality lead answer separately, then compare. Differences are the finding.

Scope written down

Name the system, version, the records it holds and the study or process in scope, so the score means something in six months.

Actions owned

Each gap gets an owner, a date and either a fix or a documented risk acceptance.

FAQ

Questions teams ask before they switch

Something not covered here? Ask us directly.

What is a 21 CFR Part 11 gap assessment?

A structured comparison of a system and its procedures against the Part 11 requirements for electronic records and signatures (audit trails, signature controls, access control, validation, record retention and copies), listing where controls are missing or unproven. This tool is a self-assessment version with 25 questions and an equal-weight score.

Does passing this assessment mean my system is Part 11 compliant?

No. It is self-reported, unweighted and evidence-free. Compliance depends on validated use, procedures, and inspection of the actual records. Use the score to find gaps and plan work, then verify with your quality function.

Is EU Annex 11 required for clinical trials?

Annex 11 is part of the EU GMP guide and applies to computerised systems in GMP activities, such as manufacturing and release of investigational medicinal products. Trial data systems are usually assessed against GCP and regulator guidance on computerised systems in clinical trials, and many sponsors use Annex 11 as a familiar benchmark. Ask your regulatory lead which texts your sponsor applies.

What changed in the revised Annex 11?

A draft revised Annex 11, together with a new Annex 22 on artificial intelligence and a revised Chapter 4, was in joint European Commission and PIC/S consultation from 7 July to 7 October 2025. Reports describe a much longer text with more emphasis on lifecycle and risk management. The 2011 version remained in force at the time of writing; check the current status on the official sites.

What does Part 11 require for electronic signatures?

In outline: signatures unique to one person (11.100), identity verified before issue, a signed record that shows printed name, date and time and the meaning of the signature (11.50), a permanent link between signature and record (11.70), and for non-biometric signatures at least two distinct identification components (11.200). Read the regulation for the exact conditions.

Why are the clock and periodic evaluation questions marked “supporting”?

Part 11 asks for time-stamped audit trails and Annex 11 asks for periodic evaluation, but neither names clock synchronisation or sets an exact evaluation frequency. We tag them as supporting practices so you can see which questions rest on the text and which on good practice.

Can I use this for a spreadsheet or survey tool?

Yes, that is the typical use. Answer for the tool as you actually run it. Most spreadsheets score low on audit trail, signatures and validation, which is the point of the exercise.

Is anything stored or sent?

No. Answers stay in the page. The printable report is generated in your browser and nothing is uploaded.

Turn gaps into working controls

Build a study in the free sandbox, change a value, sign a form and open the audit trail. No credit card; pay only at go-live.

See Part 11 controls in the free sandbox