Free tool · Phase 1 · Dose findingUpdated November 1, 2026

Dose escalation design calculator: BOIN boundaries and exact 3+3 behaviour

Enter the target dose-limiting toxicity (DLT) rate and get the BOIN escalate, stay and de-escalate boundaries, a decision table by number treated and the elimination rule. Then enter your guess at each dose’s true DLT rate and see how the classic 3+3 design would behave.

  • Liu and Yuan BOIN boundaries
  • Exact 3+3 calculation, no simulation
  • Educational planning tool

Free sandbox · No credit card · 21 CFR Part 11 compliant

  • ISO 27001 certified
  • 21 CFR Part 11 compliant
  • GDPR compliant
  • EU and US data hosting
  • HIPAA compliant
  • ICH GCP E6(R3) compliant
Demo: BOIN decision table, target DLT rate 30%
Treated at doseEscalate if DLTs ≤De-escalate if DLTs ≥Eliminate if DLTs ≥
3 patients023
6 patients134
9 patients245
12 patients257
Boundaries 0.236 and 0.359 of treated patients. Demo values from the tool.

Dose escalation designs in brief

  • A dose escalation design is a rule for the next dose. After each cohort, the rule says escalate, stay or de-escalate, based on how many patients had a dose-limiting toxicity (DLT) at the current dose.
  • BOIN (Bayesian optimal interval) turns that rule into two numbers. Escalate if the observed DLT rate is at or below λₑ, de-escalate if it is at or above λ_d, stay in between. For a 30% target, λₑ = 0.236 and λ_d = 0.359 (with the usual φ₁ = 0.6φ and φ₂ = 1.4φ).
  • The 3+3 design is a different rule with different behaviour. At a dose whose true DLT rate is 30%, the chance 3+3 escalates from it is only 49%, so it often stops below the dose you wanted.
  • An elimination rule protects patients. When Pr(true rate above target | data) exceeds 0.95, that dose and higher ones are closed. The tool prints the DLT counts that trigger it.
  • This is an educational planning tool. Real dose-finding designs are simulated, reviewed by a statistician, and run by a safety review committee. Nothing here replaces that.

Free tool

BOIN boundaries and 3+3 operating characteristics

Defaults: target DLT rate 30%, cohorts of 3, and a six-dose scenario with true DLT probabilities of 5%, 10%, 20%, 30%, 45% and 60%. Change the target for a new boundary table, or edit the dose probabilities to see how 3+3 would perform.

%
Interval limits φ₁ and φ₂

φ₁ = 18.0%, φ₂ = 42.0%.

2 to 10 doses, each between 0 and 1. Example: 0.05, 0.10, 0.20, 0.30, 0.45, 0.60

Escalate if DLT rate ≤
0.236
λₑ
De-escalate if DLT rate ≥
0.359
λ_d
BOIN decision table by number treated at the current dose
TreatedEscalate if DLTs ≤De-escalate if DLTs ≥Eliminate if DLTs ≥
3023
6134
9245
12257
15368
18479

Between the two limits the rule is to stay at the current dose. Eliminate means Pr(p > φ | data) > 0.95 under a Beta(1,1) prior: that dose and all higher doses are closed. If the lowest dose is eliminated, the trial stops.

3+3 operating characteristics for your true DLT probabilities

Exact 3+3 operating characteristics by dose
DoseTrue DLTP(escalate | reached)P(reached)P(selected as MTD)Expected patients
15%97.3%100.0%9.1%3.4
210%90.6%97.3%25.7%3.6
320%70.9%88.2%31.6%3.7
430%49.4%62.5%23.7%2.7
545%23.4%30.9%6.6%1.3
660%8.2%7.2%0.6%0.3

Expected total 15.0 patients and 2.8 DLTs. The trial ends with no dose selected (even dose 1 too toxic) with probability 2.7%. The shaded dose is the one whose true rate is closest to your 30% target; it is chosen as the MTD with probability 23.7%.

Educational planning tool, not a substitute for a statistician or a safety review committee. BOIN boundaries follow Liu and Yuan (2015); the tool does not simulate BOIN, so it does not compare the two designs' selection probabilities. The 3+3 here is the classic version: 0/3 escalate, 1/3 add three and escalate only at 1/6, otherwise stop and select the dose below (variants differ, and this one has no re-entry after de-escalation). All figures are exact calculations, run in your browser, and nothing is stored or sent.

Background

What the design has to do in phase 1

A phase 1 dose-finding study in oncology or another high-risk setting looks for the maximum tolerated dose (MTD): the dose with a DLT rate close to a target chosen in advance, commonly 25 to 33%. Participants are treated in small cohorts, each cohort receives a dose decided from the toxicity seen so far, and the study ends with an estimate of the MTD. The design determines how many patients are given doses that are too low to help, how many are given doses that are too toxic, and how often the study picks the right dose at the end. The clinical definitions of a DLT, its evaluation window and the dose levels are protocol decisions; the design is the statistical rule that uses them.

The classic rule-based design is “3+3”. It is simple to run and needs no software, which explains its long use, but it ignores the target rate (it has one built in, roughly a one-in-six to one-in-three DLT rate), uses only the data from the current dose, and tends to stop below the true MTD. Model-based designs (CRM, EWOC) fix some of that at the price of more complexity. Model-assisted designs such as BOIN occupy the middle ground: the decision rule is a table you can print and put on the wall, but it is derived from a statistical model that targets the DLT rate you choose.

The BOIN rule

How the BOIN boundaries are calculated

Liu and Yuan (2015) define two hypotheses about the DLT probability of the current dose: it is too low (φ₁) or too high (φ₂), relative to the target φ. Defaults are φ₁ = 0.6φ and φ₂ = 1.4φ, which the authors recommend as a robust choice. The boundaries are the observed DLT rates at which the posterior probabilities of the two competing decisions are equal:

λₑ = log((1 − φ₁) / (1 − φ)) / log(φ(1 − φ₁) / (φ₁(1 − φ))) and λ_d = log((1 − φ) / (1 − φ₂)) / log(φ₂(1 − φ) / (φ(1 − φ₂))).

Worked example, target 30%. φ₁ = 0.18 and φ₂ = 0.42, so λₑ = 0.2365 and λ_d = 0.3585 (shown as 0.236 and 0.359 in the tool; published tables often quote 0.358 for the second, a matter of truncation). With 3 patients at the current dose, escalate only on 0 DLTs (1/3 = 0.333 is above 0.236) and de-escalate on 2 or more (2/3 = 0.667 is above 0.359, while 1/3 sits in the stay zone). With 6 patients: escalate on 1 or fewer (1/6 = 0.167), stay on 2 (0.333), de-escalate on 3 or more. The same logic gives the whole table. For other targets: 20% gives 0.157 and 0.238; 25%, 0.197 and 0.298; 35%, 0.276 and 0.419.

Elimination. With a Beta(1,1) prior on the DLT rate, after x DLTs in n patients the posterior is Beta(1 + x, 1 + n − x). If Pr(p > φ | data) exceeds 0.95 the current and all higher doses are removed from the trial, from three patients onward. At φ = 0.30 that happens at 3 of 3 (posterior probability 0.992; 2 of 3 gives 0.916, which is not enough), 4 of 6 (0.971), 5 of 9, 7 of 12 and 9 of 18. If the lowest dose is eliminated the trial stops. The tool prints the count for every number treated in your table.

Decision table

BOIN decision table for a 30% target, by number treated

Computed by the tool with default φ₁ and φ₂. “Stay” covers every DLT count between the escalation and de-escalation limits.

Treated at doseEscalate if DLTs ≤Stay if DLTs areDe-escalate if DLTs ≥Eliminate if DLTs ≥
30123
61234
92345
1223 to 457
1534 to 568
1845 to 679

The boundaries follow the original paper; a protocol would add practical rules (a minimum number treated before escalating, a maximum per dose, overall stopping), which are design choices for a statistician.

The 3+3 design

What the classic 3+3 design does, calculated exactly

The version in the tool: treat 3 patients. If 0 have a DLT, escalate. If 1 has a DLT, treat 3 more at the same dose and escalate only if there is still just 1 DLT in 6. If 2 or more have a DLT in the first 3, or 2 or more in 6, stop. The MTD is the dose below the one that failed (variants differ on this, and on whether to retreat and expand the lower dose, which the tool does not model). With a true DLT probability p at a dose the probability of escalating from it is exactly (1 − p)³ + 3p(1 − p)⁵, because the first term is 0 of 3 and the second is 1 of 3 followed by 0 of the next 3.

Plugging in a range of p gives the escalation curve: p = 10%, 90.6%; 20%, 70.9%; 30%, 49.4%; 40%, 30.9%; 50%, 17.2%. A dose at the 30% target is therefore passed less often than not, which is the root of the design’s well-known tendency to stop low. Combining the per-dose probabilities along the path gives the chance each dose is reached, the chance the trial stops there, and so the probability each dose is selected as the MTD.

Worked scenario. True DLT rates of 5%, 10%, 20%, 30%, 45% and 60% across six doses. Dose 4 is the target (30%). The chance of escalating from each dose is 97.3%, 90.6%, 70.9%, 49.4%, 23.4% and 8.2%. The probability of selecting each dose as the MTD is 9.1%, 25.7%, 31.6%, 23.7%, 6.6% and 0.6%, with a 2.7% chance that even dose 1 is declared too toxic. The target dose is picked 24% of the time; dose 3, with a 20% DLT rate, is picked more often (32%). The expected enrolment is 15.0 patients with 2.8 DLTs.

Published simulation comparisons, including the BOIN paper, report that BOIN selects the target dose more often than 3+3 and treats fewer patients at doses that are too low. This tool does not simulate BOIN, so it does not reproduce that comparison for your scenario; if you are choosing between designs, ask a statistician to simulate both on your dose-toxicity scenarios, with your cohort size and sample size cap. The first-in-human glossary entry describes the study structure around the dose-finding part.

Quick reference

Probability that 3+3 escalates, by true DLT rate

True DLT rate at the doseP(0 of 3)P(1 of 3, then 0 of next 3)P(escalate)
5%0.8570.11697.3%
10%0.7290.17790.6%
20%0.5120.19770.9%
30%0.3430.15149.4%
40%0.2160.09330.9%
50%0.1250.04717.2%

Exact binomial arithmetic; the tool recomputes it for any set of doses you enter.

Build the DLT forms and safety review in a free sandbox

Create the dosing record, the adverse event and DLT forms and the safety alerts for your first cohort, test them with sample data, and pay only at go-live.

Set up a phase 1 study free

In Capture

The data the escalation decision depends on

Capture does not decide the next dose, and it does not run BOIN or 3+3. The safety review committee does, from the toxicity data. What Capture provides is the timely, auditable record of those data: the adverse event and DLT assessments and the alerts that bring them to the right people.

  • Adverse event and SAE capture with safety alerts that a named person acknowledges.
  • Forms for dosing, DLT assessment and cohort review built in the study builder, with edit checks and auto-queries.
  • A visit schedule with windows, so DLT evaluation periods are tracked in time.
  • A field-level audit trail, and by-site and date-range exports for the review meeting.
EDC for phase 1 clinical trials

SAE timeline

  1. SAE reported

    Day 0 · 09:12

  2. Safety alert acknowledged

    Medical monitor · 09:40

  3. Site staff attestation

    Study coordinator · 11:05

  4. AE sign-off (PI / Sub-I)

    Awaiting signature

Complete AE sign-off

Before you finalise

What to settle for a dose-escalation protocol

DLT definition and window

The adverse events that count as DLTs, their grade, and how long after dosing a patient is evaluable.

Target rate and dose levels

A target between about 20% and 33% depending on the disease and the toxicities, and the list of doses including any intermediate levels.

Cohort size and maximum sample size

The cohort size (1 to 3 is typical for BOIN), the cap per dose and the overall cap.

Starting dose and skipping rules

The first dose and whether any dose may be skipped.

Stopping and elimination rules

The overtoxicity rule and what happens if the lowest dose is eliminated.

Review and decisions

Who sees the data (the safety review committee), when, and who signs the dose decision.

Late toxicities and expansion

How toxicity after the window and any expansion cohort at the MTD are handled.

FAQ

Questions teams ask before they switch

Something not covered here? Ask us directly.

What is BOIN?

BOIN stands for Bayesian optimal interval design (Liu and Yuan, 2015). It is a model-assisted dose-finding design: after each cohort you compare the observed DLT rate at the current dose with two fixed boundaries, λₑ and λ_d, and escalate, stay or de-escalate. The boundaries come from the target DLT rate and are the same at every dose.

Where do λₑ = 0.236 and λ_d = 0.358 come from?

They are the BOIN defaults for a 30% target with φ₁ = 0.6φ = 0.18 and φ₂ = 1.4φ = 0.42. The unrounded values are 0.2365 and 0.3585; the tool shows three decimals, so you may see 0.236 and 0.359, where some tables truncate the second to 0.358.

What does the elimination rule do?

It stops treating at doses that are very likely too toxic. If the posterior probability that the true DLT rate exceeds the target is above 0.95 (Beta(1,1) prior), that dose and all higher doses are removed. At a 30% target this happens at 3 of 3, 4 of 6, 5 of 9 and so on. If the lowest dose is eliminated the trial stops.

Is the 3+3 design bad?

It is simple and transparent, which is why it is still widely used, but it has low probability of selecting the target dose and tends to stop below it, and it does not target a chosen DLT rate. The tool shows both effects: at a 30% dose the chance of escalating is 49%. Whether the trade-off is acceptable depends on the setting and on how much a statistician can support a different design.

Why does the 3+3 table show different MTD probabilities from a published one?

3+3 has several variants. This tool uses the common one: 0 of 3 escalates, 1 of 3 adds three and escalates only at 1 of 6, anything worse stops, and the MTD is the dose below the stopping dose. Variants that retreat to a lower dose and expand it give somewhat different probabilities. Use this as an approximation of the original rule.

Does the tool simulate BOIN?

No. It gives the BOIN decision boundaries and the elimination table, which are exact, and the exact 3+3 operating characteristics. BOIN operating characteristics depend on cohort size, the sample size cap and extra safety rules, and need simulation by a statistician.

Can I use my own φ₁ and φ₂?

Yes: choose Custom. The requirement is 0 < φ₁ < φ < φ₂ < 1. Widening the interval makes the decision zone “stay” larger; narrowing it makes escalation and de-escalation more reactive.

Is anything stored or sent?

No. All calculations run in your browser. The tool is educational and not validated software, and the final design belongs to the study statistician and the safety review committee.

Get the safety data flowing before cohort 1

Build the eCRFs, visit schedule and randomization in the free sandbox with nearly every feature. No credit card, pay only at go-live.

Set up a phase 1 study free