Enter the response rate not worth pursuing (p0), the rate you hope for (p1), alpha and power. The tool searches every two-stage design with exact binomial probabilities and returns the optimal and minimax designs with r1/n1, r/n, the chance of stopping early and the expected sample size.
Free sandbox · No credit card · 21 CFR Part 11 compliant
Stage 1: treat 10 participants
Count the responders
1 or fewer respond: stop
Stopping chance 74% if the true rate is 10%
2 or more respond: add 19 more
29 in all
More than 5 of 29 respond: promising
Otherwise the drug is not taken forward
Simon’s two-stage design in brief
Free tool
The default is p0 = 10%, p1 = 30%, one-sided alpha 0.05 and 80% power. The search runs in your browser and takes a fraction of a second. Press “Find designs” after changing an input.
The search is exact (binomial enumeration, no approximation) and runs here in your browser. Press Find designs after changing the inputs.
Searching designs…
Planning aid, not validated software; nothing is stored or sent. Simon (1989) rules: stop at stage 1 if responses ≤ r₁, declare the treatment promising if total responses > r. α and power are exact binomial values and are at least as strict as requested; the tool prints the achieved figures. A phase II design needs a clinical definition of response, a source for p₀ and a statistician's sign-off.
The design
Simon (1989) proposed the design for single-arm phase 2 trials in oncology, where the aim is not to prove efficacy but to decide whether an agent has enough activity to justify a randomized trial. The outcome is binary, usually an objective response, and there is no control arm: the observed response rate is compared with a historical benchmark. Three clinical decisions feed the design before any statistics. The first is the definition of response (the criteria, the assessment schedule and who reads it). The second is p0, the highest response rate that would mean “not worth pursuing”, normally taken from the historical rate of standard treatment. The third is p1, the lowest rate you would call encouraging. The gap between them sets the size of the trial.
Two error rates are controlled. Alpha is the probability of declaring a treatment promising when the true rate is only p0; the usual choices in phase 2 are 0.05 to 0.10, one-sided, because a false positive costs a phase 3 trial but is not a registration decision. Power is the probability of declaring the treatment promising when the true rate is p1, usually 80% or 90%. The design is chosen so that both constraints hold exactly.
The rule is simple to run. After n₁ participants are evaluated, the study pauses and counts responders. If the count is r₁ or lower, the study stops for lack of activity. If not, accrual continues to n participants, and the treatment is declared worth further study if the final count exceeds r. Stopping early protects patients from an inactive drug and saves money, and it is the reason the design is smaller on average than a single-stage design with the same error rates. The cost is a pause in accrual, so slow-recruiting studies sometimes prefer the minimax design, which has the smallest worst-case size.
Method
For a candidate design (r₁, n₁, r, n) the probability of declaring the drug promising when the response probability is p is the sum over stage-1 counts x above r₁ of P(X₁ = x) × P(X₂ > r − x), where X₁ is binomial(n₁, p) and X₂ is binomial(n − n₁, p). The probability of early termination is P(X₁ ≤ r₁), and the expected sample size is n₁ + (1 − PET) × (n − n₁). A design is feasible if the rejection probability at p0 is at most alpha and at p1 is at least the target power. The tool checks every n up to your search limit, every n₁ below n and every r and r₁, using exact binomial probabilities. The optimal design is the feasible one with the smallest E[N | p0]; the minimax design is the feasible one with the smallest n, ties broken by E[N | p0].
Worked example, p0 = 10%, p1 = 30%, alpha 0.05, power 80%. The optimal design is r₁/n₁ = 1/10 and r/n = 5/29. Ten participants are treated; if at most one responds, the trial stops (probability 73.6% if the true rate is 10%). Otherwise 19 more are treated and the drug is declared promising if more than 5 of 29 respond. The achieved alpha is 0.047 and the power 0.805. The expected sample size under p0 is 15.0, against a fixed 25 for the best single-stage design (more than 5 of 25 responders: alpha 0.033, power 0.807). The minimax design is 1/15 and 5/25, a maximum of 25 like the single-stage design, with an expected size of 19.5 under p0. So the optimal design saves about 10 participants on average when the drug fails, in return for a maximum of 29 rather than 25 if it does not stop.
A second check you can reproduce: p0 = 5%, p1 = 25%, alpha 0.05, power 80% gives optimal 0/9, 2/17 (expected size 11.96, PET 63%) and minimax 0/12, 2/16. These agree with the designs in Simon’s published table as far as we can check from memory (confirm against the paper). Larger response rates need larger trials: p0 = 20%, p1 = 40% gives 3/13, 12/43 optimal and 4/18, 10/33 minimax.
Because the search is exact, the achieved alpha and power are never worse than what you asked for, and they are usually slightly better, since the binomial is discrete. That is why a design for alpha 0.05 can show an achieved alpha of 0.047. Report the achieved values, not the targets, in the protocol.
Reference designs
One-sided alpha 0.05, power 80%, exact search. Format r₁/n₁, r/n; E[N] and PET are under p0.
| p0 → p1 | Optimal design | E[N | p0], PET | Minimax design | Single stage |
|---|---|---|---|---|
| 5% → 25% | 0/9, 2/17 | 12.0, 63% | 0/12, 2/16 | 2/16 |
| 10% → 30% | 1/10, 5/29 | 15.0, 74% | 1/15, 5/25 | 5/25 |
| 20% → 40% | 3/13, 12/43 | 20.6, 75% | 4/18, 10/33 | 11/35 |
| 30% → 50% | 5/15, 18/46 | 23.6, 72% | 6/19, 16/39 | 16/39 |
| 5% → 25% (alpha 0.10, power 90%) | 0/9, 2/24 | 14.5, 63% | 0/13, 2/20 | 2/20 |
Single stage means one analysis: declare promising if more than r of n respond. Reproduce any row in the tool. The last row shows how raising power to 90% and loosening alpha to 0.10 changes the designs for the same p0 and p1.
Choosing
Choose optimal when participants are plentiful and the main concern is exposing as few people as possible to an inactive drug. The cost is a larger maximum size, and in the example above 29 rather than 25 if the trial passes stage 1. Choose minimax when accrual is slow, the drug is expensive, or a fixed ceiling matters, and accept that the average size under p0 is higher (19.5 against 15.0 in the example).
Four practical points matter as much as the choice. First, the pause: the design assumes stage 1 responses are known before stage 2 begins. If accrual is fast and response assessment slow, many participants will already be enrolled when the decision arrives, and the expected savings shrink. Plan the stage 1 evaluation timing and the accrual hold in the protocol. Second, response definition and reading: independent or blinded review of responses reduces bias in a single-arm trial. Third, p0 and p1 need sources. A benchmark from a poorly matched historical population is the commonest reason a single-arm phase 2 result does not replicate in a randomized trial. Fourth, the result is a go or no-go decision, not an estimate of efficacy; confidence intervals for the response rate belong in the report, and the exact interval after a two-stage design needs a method that accounts for the stopping rule.
The design is not suitable when the endpoint is time to event, when a randomized phase 2 design is needed to control for patient selection, or when more than one dose is being compared. For endpoints where a fixed sample size and a detectable effect are the question, use the minimum detectable effect calculator; for a phase 1 dose-finding plan before this stage, see the dose escalation design calculator. The clinical trial endpoints glossary entry helps define response, and the statistical analysis plan entry lists what the plan must fix before stage 1.
Build the response form, the stage 1 data review and the visit schedule in the free sandbox, test them with sample data and pay only at go-live.
In Capture
The design runs on a clean count of responders at a planned time. Capture does not compute Simon designs; it makes the underlying data capture and review reliable, in one system with one audit trail.

For the protocol
The criteria, the timing and whether the reading is independent or blinded.
The benchmark rate and the target rate, and where each came from.
r₁/n₁, r/n, the type (optimal or minimax) and the achieved alpha and power.
When the interim count is made, who reviews it, and whether accrual is held.
Who counts as evaluable for the response count and how non-evaluable participants are replaced.
What “promising” triggers (a randomized phase 2 or 3) and the reporting of an exact interval.
It is a single-arm phase 2 design with an early stopping rule. n₁ participants are treated; if r₁ or fewer respond the trial stops for futility. Otherwise accrual continues to n participants, and the treatment is declared worth further study if more than r respond. The numbers are chosen so that the probability of a false positive at p0 is at most alpha and the power at p1 is at least the target.
Both meet the same alpha and power. The optimal design has the smallest expected sample size if the true response rate is p0, so it exposes the fewest participants to an inactive drug on average. The minimax design has the smallest maximum sample size n. In the p0 = 10%, p1 = 30% example, optimal is 1/10, 5/29 with an expected 15.0 under p0, and minimax is 1/15, 5/25 with an expected 19.5.
PET is the probability of early termination, the chance that the trial stops after stage 1, which is P(X₁ ≤ r₁). It is usually reported at p0, where a high value means the trial rapidly discards an inactive drug. In the example it is 73.6% at p0 = 10%.
The binomial distribution is discrete, so only some error rates are possible. The tool finds designs with alpha at most the value you entered and power at least the target, and shows the achieved values. Report the achieved values in the protocol.
Simon’s design tests whether the response rate exceeds p0, which is a one-sided question. Phase 2 trials commonly use one-sided alpha of 0.05 to 0.10. The choice is a protocol decision that a statistician should confirm.
The search stops at the largest n you enter. If no design is feasible, raise the limit, relax alpha or power, or increase the gap between p0 and p1. A narrow gap needs a much larger trial: p0 = 20% against p1 = 30% at alpha 0.05 and 80% power needs a minimax maximum of 116 participants.
No. The design is for a binary outcome analysed with exact binomial probabilities. For time to event, a randomized phase 2 design or a log-rank based plan is used; the survival sample size calculator covers the event count.
No. The enumeration runs in your browser. The tool is a planning aid and not validated software, and a statistician should confirm the design before it goes into a protocol.
Keep exploring
Dose escalation design calculator
BOIN boundaries and 3+3 behaviour before phase 2.
Minimum detectable effect calculator
What a fixed n can detect.
EDC for phase 2 clinical trials
Data capture for the middle phase.
EDC for oncology clinical trials
Where single-arm phase 2 designs are most common.
Survival sample size calculator
For time-to-event endpoints.
Statistical analysis plan
What to pre-specify.
Build the eCRFs, visit schedule and randomization in the free sandbox with nearly every feature. No credit card, pay only at go-live.