Use case · AI medical device validationUpdated October 12, 2026

Clinical validation study software for AI medical devices

Validating an AI device means proving that one fixed version of an algorithm performs on a defined population against an agreed ground truth, and that readers using it do no worse. Capture does not run your model. It records the cases, model version, reader sessions, ground truth and subgroup data with one audit trail. Build it free in the sandbox.

  • Model version on every case
  • Reader sessions with and without AI
  • Ground truth and adjudication

Free sandbox · No credit card · 21 CFR Part 11 aligned

Reader session design (demo: 4 readers, 2 sessions)
Session 1WashoutSession 2
Readers 1 and 2Unaided, cases A4 weeksWith AI, cases B
Readers 3 and 4With AI, cases A4 weeksUnaided, cases B
Recorded per readReader ID, case ID, modeDateFinding, confidence, time
Demo design only. Your protocol and statistical plan set the number of readers, the washout and the case split.

What an AI device validation study needs from its data capture

  • A locked model version on every case: algorithm name, version and build identifier recorded with each output, so the dataset states exactly what was tested.
  • A defined intended-use population: eligibility, case source and acquisition details recorded so the study shows the device was used as intended.
  • Ground truth with provenance: who established the reference result, from what evidence, and whether an adjudication panel resolved disagreement.
  • Reader data kept apart from algorithm data: if clinicians read with and without the device, each read is a separate record with reader, mode, order and date.
  • Subgroups built in from the start: site, acquisition device, sex, age and other pre-specified strata are baseline fields, not an afterthought.

The study design

What a clinical validation study of an AI device collects

An AI-enabled device is validated by showing that a specific, fixed version of its software gives accurate and reliable output in its intended population and setting. Two designs are common. A standalone performance study compares the algorithm’s output to a reference standard and reports measures such as sensitivity and specificity. A reader study compares clinicians with and without the device, often with several readers each reading many cases (a multi-reader multi-case design), usually with a washout interval between sessions. Studies may be retrospective on archived cases, prospective in routine care, or both. Which one you run changes what the data capture must hold, so settle it in the protocol before building forms.

The model version is the field that distinguishes this from a general diagnostic accuracy study. An algorithm that is updated mid-study is a different device. Record the model name, version and build identifier against each case or output, and add an edit check that raises a query when a version outside the declared locked version is entered. Regulators have also described change control plans for devices that will be updated after authorisation; whether one applies is a regulatory question for your team, and any change within a study should be a documented protocol amendment, not a quiet update. See ecrf versioning for mid-study changes for how form changes are handled.

Capture is the study database and does not host the algorithm, images or DICOM files. Keep images in your image archive or reader platform, and store a pseudonymised case ID and the acquisition metadata in the eCRF so the two can be joined. The device output, the reader’s finding and the ground truth are entered by the people who hold them, and the exported dataset joins them by case ID. This division also keeps personal data out of the study database where the protocol allows, which supports your GDPR obligations.

Ground truth is a process, not a field

A reference standard may be a biopsy result, a follow-up outcome, a consensus of expert readers or a laboratory assay. Record the type, the evidence date, the reader or panel, and whether the reader was blinded to the device output. If an adjudication panel resolves disagreement, keep each panelist’s call and the final decision on separate rows. Cases where no ground truth could be established should be counted with a reason, because the way indeterminate cases are handled can change performance measures.

Case record: device output and ground truth (demo)
Case 0148 · Site 006 · Retrospective setDraft

Case and model

Case ID (pseudonymised)

CASEID
C-0148

Acquisition device

ACQDEV
Scanner type B

Model name and version

MDLVER
DemoAI v2.1.0 (locked)

Device output

AIRES
PositiveNegativeIndeterminateNo output

Device score

AISCORE
0.87

Ground truth

GTRES
PositiveNegativeNot established

Adjudicated by panel, 2 of 3

Demo data only. Fields follow your protocol and statistical plan.Save
Model version sits on the case record, beside the output.

Protocol to build

AI device validation protocol elements and where they live in Capture

Protocol elementWhat the data looks likeWhere it lives in Capture
Case eligibilitySource, inclusion and exclusion criteria, intended-use fieldsEligibility form with edit checks and skip logic
Case characteristicsAge, sex, site, acquisition device, condition prevalence strataDemographics form plus a case metadata form
Model version and outputName, version, build, output, score, run dateCase eCRF form with a version edit check
Reader readsReader ID, case ID, mode (aided or unaided), session, finding, confidenceRepeating-row reader form; reader as a field
Ground truthReference type, result, evidence date, panel, adjudicationSite and adjudicator eCRF forms
Safety and device deficiencyDevice deficiency, unexpected output, patient impact if prospectiveAdverse event form and SAE report form
Data cleaning and lockQueries on missing pairs, version breaks, audit trailQuery management and database lock

Capture records the data your protocol defines. It does not run, host or validate the algorithm, and it does not decide performance.

Build the case and reader forms around your analysis plan

Upload the protocol, let the AI draft the visits and forms for review, then enter ten practice cases with a deliberate version mismatch and a missing ground truth. Free sandbox.

Build your validation study free

Quality and traceability

Reader studies, bias controls and an audit trail the reviewer can follow

Reader studies are vulnerable to order effects, memory of earlier reads and unequal case difficulty. Record the session, the date, the reader and the mode on each read, and add an edit check that raises a query if a reader appears twice on the same case in the same mode. If your design requires a washout, a check on the days between sessions makes a short washout visible to a monitor. Reader experience (years, subspecialty) is a baseline field on a reader form, so subgroup analyses by experience are possible.

Blinding matters on the ground-truth side too. The person who establishes the reference result should not see the device output if the protocol says so. In Capture, blinded roles never receive treatment-arm values, which is enforced in masked database views and row-level security. Use separate forms and roles for device output, reader reads and ground truth, and review the role-based access page. When a result is changed after the fact, for instance a re-read, the field-level audit trail shows who, when, the old and new value and the reason. This is the kind of provenance a regulatory reviewer will ask for. The audit trail software page describes how it works.

Prospective studies in routine care add the usual clinical trial duties. Eligible patients are consented (eConsent), device-related events and deficiencies are recorded and escalated, and the study may sit under a device standard such as ISO 14155; see ISO 14155 clinical investigation software and EDC for medical device clinical trials. If your device is a digital therapeutic rather than a diagnostic or triage tool, see clinical validation software for digital therapeutics. The regulatory framework for AI in the EU is described on the EU AI Act and clinical trial software page; this page does not give regulatory advice.

Build sequence

From validation protocol to a live study

A realistic order of work for a small manufacturer or an academic validation team.

  1. 1

    Draft visits and forms

    Upload the protocol (PDF, DOCX or DOC) and let the AI study builder propose the schedule and forms. Nothing is saved until a person reviews it.

  2. 2

    Build the case and model forms

    Pseudonymised case ID, case metadata, locked model version, output and score, with a version edit check.

  3. 3

    Add reader and ground-truth forms

    Repeating reader rows with mode and session, and ground-truth and adjudication forms with separate roles.

  4. 4

    Set up subgroups and exports

    Strata as baseline fields and a test export that the statistician opens in their package.

  5. 5

    Test, approve and go live

    Run practice cases through a version mismatch, a re-read and a missing ground truth, approve the forms and start the paid live phase when real data entry begins.

Sites and exports

Multi-site case collection and datasets for the statistician

Validation sets often come from several hospitals so that the device is tested across scanners and populations. Capture supports site-level participant or case numbering, a site coordinator portal and by-site filtering and exports; see multi-site clinical trial management. Source data verification can be set per field, so monitors can focus on ground truth and eligibility (risk-based monitoring and SDV).

Exports come as CSV or Excel with an automatic data dictionary, one row per submission, and CDISC SDTM export gives SAS XPT datasets with Define-XML (SDTM export, export EDC data to R, SAS and SPSS). For the sample size of a paired accuracy study, see the power analysis calculator and the non-inferiority sample size calculator as starting points; a statistician should confirm the design.

Before first case

AI device validation study readiness checklist

Model locked and identified

Name, version and build recorded in the protocol and as a controlled value in the form.

Ground-truth method fixed

Reference type, who establishes it, blinding and adjudication rules.

Operating point pre-specified

The threshold used for positive and negative output, written before data are seen.

Reader plan written

Readers, sessions, order, washout and the case split.

Subgroups pre-specified

Site, acquisition device, sex, age and any other strata listed as baseline fields.

Image storage agreed

Where images live, and how pseudonymised case IDs link them to the study record.

FAQ

Questions teams ask before they switch

Something not covered here? Ask us directly.

Does Capture run or host the AI algorithm?

No. Capture is the study database. It records cases, model version, device output, reader reads and ground truth, and it exports the joined dataset. Algorithms and images stay in your own systems.

How do we make sure only one model version is tested?

Record the model name, version and build on each case and add an edit check that raises a query when a value other than the declared locked version is entered. A real model change should go through a documented amendment.

Can we capture reader sessions with and without the AI?

Yes. A repeating-row form can hold reader ID, case ID, mode, session, date, finding and confidence, with checks for duplicate reads and short washouts.

How is this different from a diagnostic accuracy study page?

The core idea is similar, but AI validation adds model version control, aided and unaided reader sessions, subgroup strata and a clear line between algorithm output and clinician reads. See the diagnostic accuracy page for the index-test and reference-standard basics.

Is Capture a regulatory submission tool?

No. It captures and exports study data with an audit trail. Regulatory strategy, submissions and obligations under device and AI rules are separate work, and this page is not regulatory advice.

Is the platform 21 CFR Part 11 compliant?

Capture provides 21 CFR Part 11-aligned controls: a field-level audit trail, electronic signatures and role-based access. Compliance is shared with the sponsor’s own validated use of the system. This is not legal advice.

Start building your study free

Free sandbox with every feature. No credit card, and you pay only when you go live with real participants.