Eye trials collect everything twice, once per eye, and analyse one of them. Capture records IOP, visual fields, letter scores and OCT thickness by eye, with the study eye fixed at screening and every change audit-trailed. Build and test free.
Free sandbox · No credit card · 21 CFR Part 11 compliant
Dosing and timing
Last dose of study drops
LDOSDTCIOP measured
IOPDTCHours since last dose
IOPHRSHours between two date-times, read-only
12.1 h CalculatedMethod
IOPMETHIntraocular pressure
IOP, right eye (OD)
IOPODIOP, left eye (OS), study eye
IOPOSRepeat readings taken
IOPREPWhat a glaucoma or AMD trial needs from its EDC
Data structure
There are two ways to build ophthalmic forms, and both work in Capture. The paired layout puts an OD field and an OS field side by side for each measure (IOP right eye, IOP left eye), which is quick to enter and gives one row per visit in the export. The row-per-eye layout uses a repeating table with an eye field and one row per eye, which is tidier when the number of measures per eye is large, as with visual field indices or OCT parameters. Pick one convention for the study and say in the data dictionary how the analysis identifies the study eye. In SDTM, laterality is carried in its own variable (LAT), which maps naturally from either layout; Capture exports SDTM as SAS XPT with Define-XML.
The study eye is chosen once, at screening, by the rule your protocol states: the eye meeting criteria, the worse eye if both qualify, or the right eye by default. Put the choice and the rule used on the screening form. Skip logic can then show the study-eye label on every later form, so a coordinator entering OCT at month 6 sees which eye the endpoint is about. If the fellow eye is treated under the protocol, give it its own treatment and safety records. Eye-level adverse events need an eye field on the adverse event form. The same design is used on EDC for diabetic retinopathy trials and, for a paediatric refractive design, EDC for myopia control trials.
Every change to an eye-level value keeps its audit record: old value, new value, user, time and reason. That matters when a coordinator realises at the next visit that last month's right and left values were swapped. The correction is visible, explained and exportable, rather than a silent overwrite. Source data verification can be set per field, so a monitor can verify the IOP and BCVA fields at every visit and sample the rest; see source data verification.
Glaucoma
IOP-lowering trials usually measure pressure by Goldmann applanation at several fixed times on each assessment day (an early-morning, late-morning and afternoon reading is a common pattern) at several visits, and compare mean IOP between arms. Diurnal variation means an 08:00 value and a 16:00 value are different measurements, so record the time point as a field, not just the visit. Many protocols take two readings and a third if they differ by more than a set amount; record each reading and let the analysis take the mean. The time since the last dose of study drops is a calculated field built from two date-times, so a reading taken at the wrong point after dosing is visible at entry. Central corneal thickness in micrometres is often collected once because it affects applanation readings.
Visual fields from standard automated perimetry produce a set of indices per eye: mean deviation and pattern standard deviation in decibels, often a visual field index as a percentage, and reliability indices (fixation losses, false-positive and false-negative rates). The protocol sets the reliability thresholds and how many fields confirm progression. Put all of these on the form, with the test pattern and the test date, so an unreliable field can be excluded by rule. The IOP and visual field template has these fields. Capture does not connect to perimeters or OCT devices; values are entered from the printout or loaded through your own data process. Optic nerve structure (cup-to-disc ratio, RNFL thickness in micrometres) completes the picture in progression studies.
Washout is the screening problem specific to glaucoma. Participants on IOP-lowering drops stop them for a class-specific period before baseline, under safety monitoring. Record each prior medication with stop date on the concomitant medications form, and add a date-order rule so the baseline visit cannot precede the end of washout. A range check on screening IOP flags pressures outside the eligibility window, and another can raise a query on a washout reading high enough to need the safety action your protocol describes.
Protocol to build
| Assessment | What the data looks like | Where it lives in Capture |
|---|---|---|
| Study eye designation | OD or OS, rule used, date | Screening form; reused by skip logic on later forms |
| IOP | mmHg per eye per time point, method, readings, time since dose | Paired OD/OS fields per time point; calculated hours since dose |
| Visual field | MD and PSD in dB, VFI %, fixation losses, false positives, false negatives, pattern | Row per eye with reliability fields; IOP and visual field template |
| BCVA | ETDRS letters per eye, test distance, examiner | Numeric field with a range check on the chart maximum |
| OCT | Central subfield thickness or RNFL thickness in um, fluid present yes/no | Row per eye; device field if more than one is allowed |
| Geographic atrophy lesion | Area in mm2 from the reading centre report, image date | Form entered from the report, with grading date |
| Intravitreal injection or sham | Eye, date-time, lot, post-procedure IOP, complications | Repeating row in a form only the unmasked role opens |
| Prior glaucoma medication and washout | Drug class, stop date | Concomitant medications with date-order rules |
| Ocular adverse events | Eye, onset, severity, relationship | Adverse event form with an eye field |
Capture does not read images, grade OCT or calculate mean IOP, field progression or lesion growth. Those come from the reading centre or the analysis.
Set the study eye at screening, enter IOP at three time points, swap two values and watch the audit trail. Free sandbox, no credit card.
Macular degeneration
Neovascular AMD trials of intravitreal treatments commonly use mean change in BCVA in ETDRS letters at about one year as the primary endpoint, often in a non-inferiority design, with central subfield thickness, the presence of intraretinal or subretinal fluid and the number of injections as key secondaries. Treatment intervals may be extended or shortened by disease activity criteria at each visit, so the form needs the criteria assessed and the interval decided, not just the date of the next injection. Record the examiner role and refraction date for BCVA so method changes are visible.
Geographic atrophy trials measure the growth of the atrophic lesion, usually as area in square millimetres from fundus autofluorescence graded at a reading centre. Like other graded endpoints, the value arrives in a report: enter the area, image date and grading date on a dedicated form so a missing or ungradable image is a visible gap. Capture holds that dated record; it does not grade images.
Injection and sham procedures are where masking breaks. The injecting clinician is unmasked; the examiner measuring letters is not. Capture supports blinded roles that never receive treatment-arm values, enforced in the database through masked views and row-level security, so put the procedure record in a form only the unmasked role opens; see blinded and unblinded role management. Post-injection IOP gets a range rule that raises a query above the threshold you set, and intraocular inflammation, endophthalmitis and retinal detachment route to the serious adverse event workflow. Older participants may prefer to review consent at home first with eConsent.
Build sequence
Paired OD/OS fields or a repeating row per eye, and how the analysis identifies the study eye.
Upload the protocol (PDF, DOCX or DOC) and let the AI study builder propose visits and forms. Nothing is saved until a person reviews it.
Record the eye and the rule, then show it on every later form with skip logic.
IOP time points with hours since dose, range checks on IOP, letters and thickness, and date-order rules for washout.
Procedures in an unmasked-only form; test the masked view with a dummy participant.
Enter a swapped-eye correction, an unreliable field and a high post-injection IOP, then export.
Before first participant
Screening form records the eye and how it was chosen.
Time points, readings per time point and dosing window on the form.
Thresholds from the protocol written into the data review plan.
Who enters graded values, with image and grading dates.
Masked login checked against the procedure form.
Per-eye data opened by the statistician; SDTM with Define-XML if needed.
Either as paired OD and OS fields on each form or as a repeating row per eye with an eye field. Both keep a field-level audit trail. Choose one convention and document it in the data dictionary.
No. Capture stores each reading, time point and index. The only calculated field shown here is the hours between two date-times, such as time since the last dose. Means and progression are derived in the analysis.
No device integration is claimed. Values are entered from the device output or loaded through your own data process.
Yes. Blinded roles never receive treatment-arm values, enforced by masked database views. Keep the procedure record in a form only the unmasked role opens.
Yes. Visits with windows run for as long as the protocol needs, with the same participant ID throughout, and exports filter by date range and site.
Yes. Capture exports CDISC SDTM as SAS XPT files with Define-XML, alongside CSV and Excel with an automatic data dictionary.
The sandbox is free with every feature, no credit card. You pay only when you go live with real participants; see the pricing page.
Keep exploring
IOP and visual field template
Per-eye pressure and field fields.
EDC for diabetic retinopathy trials
Graded retinal endpoints.
EDC for myopia control trials
A paediatric eye-level design.
Blinded and unblinded roles
Keep the examiner masked.
Concomitant medications template
Prior drops and washout dates.
EDC for medical device trials
For implant and laser studies.
Free sandbox with every feature. No credit card.