Apply the four significant-risk criteria in 21 CFR 812.3(m) and the exemption categories in 812.2(c) to your study. The tool gives a likely outcome, the reasoning, and the path: IDE with FDA approval, or abbreviated requirements under the IRB. Not an FDA or IRB determination.
Free sandbox · No credit card · 21 CFR Part 11 compliant
| Significant risk | Non-significant risk | Exempt | |
|---|---|---|---|
| IDE application to FDA | |||
| IRB approval | ask IRB | ||
| Informed consent (Part 50) | ask IRB | ||
| Abbreviated requirements 812.2(b) | |||
| Who decides | FDA / IRB | IRB (FDA if asked) | Sponsor, check 812.2(c) |
Significant risk in brief
Free tool
The demo describes an implant that is of substantial importance in treating disease and is judged to carry potential for serious risk, which gives SR. Change the answers to see the result move. Nothing is saved or sent.
Think about the procedure, the energy or delivery involved, the duration and the population.
Why
What follows
Planning aid, not legal advice or an FDA or IRB determination. The IRB makes its own decision on a non-significant risk study. Check the current text of 21 CFR 812 and FDA's significant risk and nonsignificant risk information sheet. Runs in your browser; nothing is stored or sent.
The method
The tool applies a fixed order. First, if FDA has already decided, that decision is final and the tool reports it. Second, if you tick an exemption category from 812.2(c), the tool reports possibly exempt and lists the category, because each category has conditions you must read in the current paragraph. Third, it looks at the potential for serious risk in this study. Every one of the four routes ends in the same test, so a Yes on the final question (“potential for serious risk as used in this study”) gives SR and the tool lists which routes your answers also match. A No, with no unclear answer on the other three questions, gives NSR. Anything unclear gives “cannot call it”, because guessing here is the costly error.
An implant is not automatically SR, and a diagnostic device is not automatically NSR. The first three routes each contain the words “and presents a potential for serious risk”. A dental implant used in a minimal-risk placement may be NSR, whereas a novel non-invasive sensor that drives a treatment decision may carry serious risk if a wrong reading leads to harm. That is why the tool asks the risk question last and separately.
A fully implanted neurostimulator for a first-in-human indication: implant, treating disease, potential for serious risk. SR, so the sponsor needs an approved IDE and IRB approval. A wearable skin thermometer already cleared and used within its labeling to collect temperature in a drug trial: a legally marketed device used per its labeling, so possibly exempt under 812.2(c), with the IRB still asked about consent. A new non-invasive optical sensor that records data but is not used for treatment decisions and introduces no energy risk: probably NSR, which the sponsor explains to the IRB and the IRB confirms or overturns. These are teaching examples, not rulings.
What changes
| Significant risk | Non-significant risk | Exempt (812.2(c)) | |
|---|---|---|---|
| FDA role | Approves the IDE before the study starts | No application; FDA can be asked for a determination | No IDE; FDA can be asked if unsure |
| IRB role | Approves the study, including the SR decision | Makes its own SR or NSR determination on the sponsor’s rationale | Reviews as required by Parts 50 and 56 where they apply |
| Core regulation | Full Part 812 | Abbreviated requirements, 812.2(b) | Most of Part 812 does not apply, with limited exceptions |
| Labeling and promotion | Investigational labeling and promotion limits | Labeling (812.5) and promotion limits (812.7) | Check the category |
| Monitoring and records | Sponsor monitoring, records and reports | Monitoring (812.46), records and reports | Check the category |
| If the IRB disagrees | IDE needed first | If the IRB finds SR, an IDE is needed before the study starts | Ask FDA |
Section numbers follow the text we could check through summaries; confirm them in the current eCFR. See the [Part 11 checklist](/solutions/21-cfr-part-11-compliance-checklist) for electronic records in device studies.
Build the visit schedule and device-event forms in the free sandbox so the protocol and the data plan agree. No credit card.
After the tool
FDA’s information sheet on significant risk and nonsignificant risk medical device studies (the copy we found was dated 2006) is the document to read next. It explains that the sponsor makes the initial NSR assessment and presents it to the IRB, that the IRB must make its own determination, and that FDA’s determination is final if it has made one. It also gives examples of SR and NSR devices. If the sponsor and the IRB disagree, or the call is close, you can ask FDA for a study risk determination through the pre-submission programme; check FDA’s current process for how to file one.
Document the rationale in the same terms as the regulation: the device, its use in this study, the procedure, energy or delivery involved, the population and the reasons you consider the risk non-serious. That one page serves the IRB, the monitor and any later inspector. For studies in the early stage of a device’s life read early feasibility and pivotal device study EDC, and for the wider process how to run a medical device clinical study. For EU plans, use the EU MDR clinical investigation route finder. Software that is itself a device is covered in the SaMD glossary entry.
An SR or NSR label is a starting point for the quality system, not the end of it. Informed consent under Part 50, IRB approval and electronic records controls apply across all three outcomes, with different amounts of FDA involvement.
In Capture
Capture does not make the SR or NSR decision or file an IDE. When the study is running, it collects the data with Part 11-compliant controls and one audit trail.
Edit checks / auto-queries
2Type
Range High
Operator
Greater than
Value
180
Priority: High
Type
Range Low
Operator
Less than
Value
80
Priority: Normal
Query raised automatically
Value 192 violates limit (180). Please verify.
Rationale
What it is, how it works, and whether it is cleared or approved for any use.
Procedure, duration, energy or delivery, and who it is used on.
Implant, life-supporting, substantial importance, or otherwise serious risk.
Bench, animal and prior clinical data, and mitigations.
Which 812.2(c) category you checked and why it does or does not fit.
Sponsor view, IRB decision with date, and any FDA contact.
Under 21 CFR 812.3(m) the device presents a potential for serious risk to the health, safety or welfare of a subject. The definition lists an implant, a device that supports or sustains human life, and a device of substantial importance in diagnosing, curing, mitigating or treating disease or preventing impairment of health, each with a potential for serious risk, plus a catch-all for any other device with that potential. Confirm the wording in the current text.
The sponsor makes the first assessment and presents it to the IRB, which makes its own determination. If FDA has made the determination for the study, FDA’s decision is final. Either FDA or the IRB finding significant risk means an approved IDE is needed before the study starts.
No IDE application goes to FDA, but the abbreviated requirements in 812.2(b) apply: labeling, IRB approval with the NSR finding, informed consent, monitoring, records and reports, and the promotion limits. Check the current text for the full list.
No. The implant route applies where the implant presents a potential for serious risk to subjects as used in the study. Many implants are SR, but the determination turns on the study, so an implant in a low-risk use can be NSR.
Section 812.2(c) lists categories, including a legally marketed device used in accordance with its labeling, certain diagnostic devices tested non-invasively, certain consumer-preference or modification tests, veterinary and animal research and custom devices. Each has conditions, and Parts 50 and 56 can still apply, so read the paragraph before relying on an exemption.
If the IRB decides the device is significant risk, an approved IDE is needed before the study can start, and you should follow FDA’s information sheet on what to tell the agency. Document the disagreement and the reasoning.
Yes. Sponsors can ask FDA for a study risk determination, commonly through the pre-submission programme. Check FDA’s current instructions for the format and timing.
No. Your answers stay in your browser. This is a planning aid and not an FDA or IRB determination.
Keep exploring
How to run a medical device clinical study
The end-to-end process.
Early feasibility and pivotal device study EDC
Data capture by study stage.
EDC for medical device clinical trials
Device-specific data collection.
EU MDR clinical investigation route finder
The EU counterpart of this decision.
ISO 14155 clinical investigation software
GCP for device investigations.
IND exemption checker
The drug-side question.
Build visits, device-event forms and consent in the free sandbox and test them with sample data. No credit card; you pay only when you go live.