Heart rate, PR, QRS and QT go in; QTc by Bazett and Fridericia come out read-only, so no one copies a number off the machine printout by hand. Rhythm, a normal / abnormal not clinically significant / abnormal clinically significant interpretation, and a table for triplicate tracings are built in.
Free sandbox · No credit card · 21 CFR Part 11 compliant
Intervals (machine read)
Heart rate
EGHRPR interval
PRAGQRS duration
QRSAGQT interval
QTAGQTc Bazett
QTCBAGQTc Fridericia
QTCFAGInterpretation
Rhythm
Overall interpretation
2
QTc corrections calculated: Bazett and Fridericia
3
interpretation levels: normal, NCS, CS
1
row per tracing, each with its own audit trail
EG
SDTM domain the form is labelled with
What this template gives you
Design basics
An ECG form has two jobs. It stores the numbers a statistician will analyse (intervals and corrected QT at each time point) and it records the investigator’s safety judgement on the day (is this tracing acceptable for the participant to continue?). Good ECG forms keep the two apart: measured values in numeric fields with fixed units, the judgement in a coded interpretation field, and free text only for describing an abnormality.
Most of the queries on ECG data come from three sources: a QTc typed from the printout that does not match the QT and heart rate on the same form, missing context (was the participant supine and rested, was this pre-dose or two hours post-dose?), and an abnormal tracing marked clinically significant without a matching adverse event. The template removes the first by calculating QTc, prompts for the second with required context fields, and flags the third with an edit check.
ECGs usually sit next to vital signs on the schedule, so the two forms share conventions: fixed units, position and time recorded, and repeat readings as table rows. See the vital signs eCRF template for the companion form and the physical exam eCRF for the cardiovascular examination findings that often go with a screening ECG.
Both correct the QT interval for heart rate using RR, the time between beats in seconds (60 ÷ heart rate). Bazett divides QT by the square root of RR; Fridericia divides by the cube root. At a heart rate of 72 and a QT of 380 ms, RR is 0.833 s, Bazett gives 416 ms and Fridericia 404 ms. At 110 beats per minute and a QT of 330 ms the gap widens: Bazett 447 ms, Fridericia 404 ms. Bazett over-corrects at faster heart rates, which is why many drug trials take Fridericia as the primary correction. In cardiac-focused studies the same form sits alongside the endpoint forms described in EDC for cardiology trials. The template stores both; your statistical analysis plan names which one counts. The QTc calculator shows the formulas side by side.
Many sites record the intervals printed by the ECG machine. Some protocols ask for a manual over-read by a cardiologist, and many drug trials send tracings to a central ECG laboratory that measures them in a blinded, consistent way. The template records the method in a field per tracing. When a central laboratory reads the ECGs, its measurements usually arrive as a separate data transfer agreed with the sponsor; the eCRF then keeps the site’s local read and safety interpretation, which is what the investigator acts on during the visit.
BMI (Body Mass Index)
Auto-derivedHeight (cm)
172
Weight (kg)
68.5
Result
23.2 kg/m²
Reference: WHO · shown read-only during data entry
Template
Default ranges are wide on purpose: they catch typing and unit errors, not clinical abnormality. Tighten them for your population and add protocol alert limits where the protocol defines them.
| Field | Question type | Values / unit | Default check or rule |
|---|---|---|---|
| ECG performed | Single choice | Yes, no (reason) | No hides the rest of the form (skip logic) |
| Date and time of ECG | Date, time | Date, hh:mm | Required; time needed for post-dose time points |
| Planned time point | Dropdown | Screening, pre-dose, 1 h, 2 h ... post-dose | From your schedule of assessments |
| Position and rest | Single choice, number | Supine, semi-recumbent; minutes of rest | Help text states the protocol’s rest time |
| Read method | Single choice | Machine, manual over-read | Required |
| Read by | Single choice | Local site, central laboratory | Required |
| Heart rate | Number | beats/min, integer | Range 30 to 200 |
| PR interval | Number | ms, integer | Range 80 to 400; blank allowed in atrial fibrillation |
| QRS duration | Number | ms, integer | Range 40 to 250 |
| QT interval | Number | ms, integer | Range 200 to 700 |
| RR interval (optional) | Number | ms | Keep if your machine reports it; QTc uses heart rate |
| QTc Bazett (QTcB) | Calculated | ms | Read-only, from QT and heart rate |
| QTc Fridericia (QTcF) | Calculated | ms | Read-only, from QT and heart rate; optional alert limit, e.g. above 500 ms |
| Rhythm | Dropdown | Sinus rhythm, sinus bradycardia, sinus tachycardia, atrial fibrillation, other (specify) | Other opens a text field |
| Overall interpretation | Single choice | Normal; abnormal, not clinically significant; abnormal, clinically significant | Required |
| Abnormal findings | Long text | Free text | Shown when interpretation is abnormal |
| CS finding recorded as AE? | Single choice | Yes (AE number), no (reason), pre-existing in medical history | Shown when CS; custom check raises a query if left blank |
| Reviewed by investigator | Text, date | Name, date | Supports investigator sign-off on safety data |
Variable codes such as QTCFAG are examples in the style of SDTM EG test codes. The form carries the EG domain label; Capture’s SDTM export produces the EG dataset as SAS XPT with Define-XML.
Triplicate ECGs
Many drug trials take ECGs in triplicate: three tracings a minute or two apart at each time point, with the participant resting supine, and analyse the mean of the three. Typing a mean into a single field loses the individual values and cannot be checked. The template instead uses a table section: each row is one tracing with its own time, heart rate, PR, QRS, QT and calculated QTc. Every row carries its own audit trail, so a corrected value in tracing two is visible as a change to that row.
In the demo below the three tracings give QTcF values of 404.2, 404.5 and 403.8 ms; the mean, 404 ms, is computed in analysis from the exported rows rather than stored on the form, because Capture’s calculated fields are a fixed clinical list (QTc, eGFR, BMI and others), not a free formula engine. Set the minimum and maximum number of rows to three if your protocol requires exactly three tracings, so a missing one is obvious at entry.
Thresholds used in QT analysis come from ICH E14, which describes categorical analyses such as QTc above 450, 480 and 500 ms and increases from baseline of more than 30 and 60 ms. These are analysis categories, not entry rules. On the form, an alert limit on a single QTcF value, for example above 500 ms, is the practical edit check; the change from baseline is calculated in analysis or by the central laboratory.
Tracing 1 · 08:02
Heart rate / QT
QTcF
QTCFAGTracing 2 · 08:04
Heart rate / QT
QTcF
QTCFAGTracing 3 · 08:06
Heart rate / QT
QTcF
QTCFAGOn the schedule
Phase 1 studies often take ECGs at several post-dose time points on dosing days; later-phase studies may need them only at screening, baseline and a few safety visits. Build the form once, place it on each visit in the schedule, and use the planned time point field to tell the post-dose readings apart. Visit windows flag late visits, and the status overview shows which participants are missing an ECG at which visit.
| Assessment | Scr | D1 pre | D1 1h | D1 2h | D1 4h | D2 | FU |
|---|---|---|---|---|---|---|---|
| 12-lead ECG (triplicate) | |||||||
| Vital signs | |||||||
| PK sample | |||||||
| Physical exam |
The ECG form, its calculated fields and edit checks work in the free sandbox. No credit card, no time limit.
Before you approve the form
Fridericia, Bazett or both, as the statistical analysis plan says. Keep both calculated; analyse the one named.
Every planned post-dose time point in the dropdown, matching the protocol’s schedule of assessments.
Table rows fixed at three if the protocol requires triplicates; one row otherwise.
Machine or manual, local or central, on every tracing.
A custom edit check queries a clinically significant finding with no AE number or reason.
Wide typo ranges on every interval, plus any protocol alert limit on QTcF.
If a central laboratory reads the tracings, the data transfer agreement says how its data join the study data.
Date and time, position and rest, time point, heart rate, PR, QRS, QT, corrected QT, rhythm and an overall interpretation (normal, abnormal not clinically significant, abnormal clinically significant), plus who read it and how. Add RR if your machine reports it.
Yes. QTc by Bazett and by Fridericia are built-in calculated fields. Map them to the QT and heart rate questions and they appear read-only during entry. Calculated fields are excluded from source data verification because they are derived from verified fields.
Use the table section: one row per tracing with its own time, intervals and calculated QTc. Each row has its own audit trail. The mean of the three is computed in analysis from the exported rows.
They are the investigator’s judgement on an abnormal tracing: not clinically significant (an abnormality with no clinical consequence for this participant) or clinically significant. Protocols usually require a clinically significant new or worsened finding to be reported as an adverse event.
This template is for site entry; Capture does not claim a direct ECG machine or central laboratory integration. Central laboratory data usually arrive as an agreed data transfer, and the eCRF keeps the site’s local read and safety interpretation.
EG (ECG test results). The form carries the EG domain label and an OID, and Capture’s SDTM export produces SAS XPT datasets with Define-XML.
Many protocols treat a QTcF above 500 ms, or a large increase from baseline, as a safety signal, in line with the categorical analyses described in ICH E14. Put a single-value alert limit on QTcF as an edit check if your protocol defines one; changes from baseline are calculated in analysis.
Yes. Copy it in the free sandbox, change the fields to your protocol, test it with sample data and only pay when you go live with real participants.
Keep exploring
Vital signs eCRF template
The form that sits next to the ECG at most visits.
Physical exam eCRF template
Body systems, including the cardiovascular exam.
QTc calculator
Bazett, Fridericia and other corrections side by side.
Adverse event eCRF template
Where clinically significant findings are reported.
EDC for cardiology trials
ECG, QTc and cardiac endpoints in a full study.
Edit checks software
Range and custom checks that raise queries.
Copy the ECG template, map QT and heart rate, and let the form calculate QTcB and QTcF. Free sandbox, no credit card.