A companion diagnostic is a medical device, usually an in vitro diagnostic test, that provides information essential for the safe and effective use of a corresponding drug or biologic. It typically decides which patients should, or should not, receive the treatment.
Free sandbox · No credit card · 21 CFR Part 11 compliant
Companion diagnostic
noun · clinical research
A diagnostic device, often an in vitro test, that provides information essential for the safe and effective use of a corresponding therapeutic product, and is named in that product’s labelling.
Related terms
In short
Definition
FDA’s 2014 guidance on in vitro companion diagnostic devices, and its current companion diagnostics page, describe a CDx as a device that provides information essential for the safe and effective use of a corresponding therapeutic product. The word "essential" is the dividing line. If the drug’s labelling says a patient must test positive, or must be tested, before treatment, the test is a companion diagnostic. Tests that are useful but not required fall outside the definition.
Most companion diagnostics measure a biomarker: a gene mutation, a protein expression level, a fusion, or another marker that predicts response or risk. They are most common in oncology, where targeted therapies work only in tumours carrying a specific alteration (oncology data capture), but they exist in other areas too. Because a wrong result can mean a patient gets an ineffective drug or misses an effective one, companion diagnostics are usually treated as higher-risk devices in the US and often go through premarket approval (see 510(k), PMA and De Novo). Check FDA’s current guidance for the route that applies.
FDA lists the situations in which a test can be essential for a drug’s safe and effective use.
Companion vs complementary
The terms are often confused. The practical difference is whether testing is required before the drug can be used.
| Aspect | Companion diagnostic | Complementary diagnostic |
|---|---|---|
| Required before prescribing? | Yes, per the drug labelling | No |
| What it informs | Eligibility, safety or monitoring that is essential | Benefit-risk decisions; identifies a subgroup with greater benefit |
| Typical trial design | Enrichment: only marker-positive patients enrolled | All-comers, analysed by marker status |
| Regulatory definition | FDA guidance definition; defined in EU IVDR | No formal FDA regulatory definition; check current guidance |
Summary for orientation. Check the current FDA and EU texts for your product.
Co-development
The ideal is contemporaneous development: the drug sponsor and the diagnostic developer agree on the biomarker, the cut-off and the assay early, use the same analytically validated assay to select patients in the pivotal trial, and submit both for approval at about the same time so the drug label and the device label refer to each other.
In practice, early trials often use a laboratory assay that is not the final commercial test. When that happens, a bridging study retests stored samples with the final assay to show agreement with the clinical trial assay. That is only possible if the samples, consent for retesting and the original results were all kept and linked to participants, which is a data management issue as much as a laboratory one.
In the EU, companion diagnostics are regulated under the In Vitro Diagnostic Medical Devices Regulation (EU) 2017/746 (IVDR), which defines the term and classifies companion diagnostics as at least class C. A notified body assesses the device and, before issuing its certificate, consults the medicines authority: the EMA when the medicine goes through the centralised procedure, or a national competent authority otherwise. Transition timelines under the IVDR have been extended more than once, so check the current text and EMA’s companion diagnostics page for what applies.
A test used to choose treatment in a trial before it is approved is an investigational device. In the US, depending on risk, its use may need an investigational device exemption or can be covered within the drug’s IND. Clarify this with the regulator early, because it affects the protocol and timelines.
Trial data
These fields make enrichment, stratification and later bridging studies possible.
Positive, negative, indeterminate or not evaluable, including for screen failures.
Clinical trial assay or final CDx, kit lot or version, and the cut-off applied.
Central or local lab, so results can be grouped and compared.
Sample type, collection date and sample ID linked to the participant ID, for retesting.
Proof that status was known before eligibility was confirmed.
If biomarker status is a stratification factor, record the value used at randomisation.
Whether the participant agreed to sample storage and future testing.
Create a screening form with biomarker status, assay and sample fields in the free sandbox, add eligibility edit checks and test them with dummy patients. No credit card, no time limit.
In Capture
Capture is a self-serve EDC for Phase 1 through Phase 3. Build the screening form with biomarker status, assay and sample fields, use skip logic so assay details appear only when a sample was tested, and add edit checks that raise an auto-query when, for example, a participant is marked eligible without a positive result. Randomization sits in the same system, consent can be collected through eConsent, and every change carries a field-level audit trail. Exports include a data dictionary, and SDTM datasets come as SAS XPT with Define-XML.
Sample type
Assay used
Testing lab
Biomarker status
LBORRESResult date
A test you must take before a particular drug can be used, because the result shows whether the drug is likely to work for you or likely to harm you.
No. Many detect gene mutations, but others measure protein expression or other biomarkers, and FDA’s definition also covers imaging and other device types.
A companion diagnostic is required for safe and effective use of the drug. A complementary diagnostic gives useful information about benefit and risk but testing is not required before prescribing.
Because the test defines who the drug works for. Using the same assay in the pivotal trial and on the market avoids having to prove later that a different test selects the same patients.
Under the IVDR (Regulation (EU) 2017/746), as at least class C devices assessed by a notified body, which consults EMA or a national medicines authority before certifying. Check the current transition rules.
A trial that enrols only patients with a particular biomarker result, usually marker-positive, so the treatment effect is studied in the group expected to benefit.
Keep exploring
Biomarker
What most CDx tests measure.
Investigational device exemption
When an unapproved test is used in a trial.
510(k), PMA and De Novo
US device routes.
EDC for diagnostic accuracy studies
Validating a test.
Eligibility criteria checker
Test eligibility logic.
EDC for oncology trials
Where most CDx trials run.
Free sandbox with every feature. Build screening forms, edit checks and randomization, and enter dummy patients. No credit card, no time limit.