An investigational device exemption (IDE) lets an unapproved medical device, or an approved device used in a new way, be used in a clinical study in the United States to collect safety and effectiveness data. The rules are in 21 CFR Part 812, and how much FDA is involved depends on the device’s risk.
Free sandbox · No credit card · 21 CFR Part 11 compliant
Is the study exempt under 812.2(c)?
For example, a cleared device used per its labelling
Significant risk device?
Sponsor proposes, IRB decides, FDA can be asked
Non-significant risk
Abbreviated requirements, IRB approval only
Significant risk
IDE application to FDA, plus IRB approval
In short
Explained
Federal law generally prohibits shipping a device that is not cleared or approved. An IDE exempts an investigational device from that and from several other device requirements so that it can be studied in people. 21 CFR 812.2(a) says Part 812 applies to all clinical investigations of devices to determine safety and effectiveness, with the exceptions in 812.2(c). For a significant risk study, the sponsor files an IDE application with FDA; under 21 CFR 812.30 an investigation may begin 30 days after FDA receives the application unless FDA notifies the sponsor otherwise, and IRB approval is also required. Check the current eCFR text for the details.
Once the study is running, the IDE governs it: who may receive the device (only investigators under a signed investigator agreement), how it is labelled ("CAUTION Investigational device. Limited by Federal (or United States) law to investigational use"), how it is tracked and returned, how the study is monitored, and what is reported to FDA and the IRB, such as unanticipated adverse device effects. The data then feed a marketing submission; see 510(k), PMA and De Novo for the routes.
The sponsor makes an initial risk assessment and presents it to the IRB with the protocol. If the IRB agrees the device is non-significant risk, the study can run under the abbreviated requirements without an application to FDA. If the IRB decides it is significant risk, the sponsor must report that to FDA (university guidance cites five working days) and the full IDE route applies. Sponsors who are unsure can ask FDA for a risk determination. Note that the determination is about the device as used in this study, not about the device’s classification. Our significant risk device determination tool walks through the questions.
Under 21 CFR 812.2(b), a non-significant risk study is treated as having an approved IDE as long as the sponsor meets a short list of conditions: the device is not a banned device, it is labelled under 812.5, IRB approval is obtained with an explanation of why the device is non-significant risk, informed consent is obtained under Part 50, the study is monitored under 812.46, certain records and reports are kept, and the device is not promoted, commercialised or represented as safe and effective. Many academic device studies run this way.
Compared
| Exempt (812.2(c)) | Non-significant risk | Significant risk | |
|---|---|---|---|
| FDA application | No | No (abbreviated requirements) | Yes, IDE application |
| IRB approval | Still required where Parts 50 and 56 apply | Yes | Yes |
| Informed consent | Required where Part 50 applies | Yes | Yes |
| Monitoring and records | Not under Part 812 | Yes, simplified | Yes, full |
| Examples (illustrative) | Cleared device used per its labelling | Many low-risk accessories or software tools | Implants, life-supporting devices |
Illustrative only. Read 21 CFR 812.2 and 812.3(m) and ask FDA if unsure.
Exemptions
21 CFR 812.2(c) lists categories exempt from Part 812. They include certain devices in commercial distribution before May 1976 and devices found substantially equivalent to them, used per their labelling; devices legally marketed and used in accordance with their labelling; many diagnostic devices that meet specific conditions (for example, noninvasive, not requiring an invasive sampling procedure that presents significant risk, not introducing energy into a person, and not used as a diagnostic procedure without confirmation by another medically established product or procedure); consumer preference and similar testing that does not determine safety or effectiveness and does not put participants at risk; veterinary devices; devices for research on laboratory animals; and custom devices, unless used to support marketing. Every condition in a category must be met, and the IND exemption checker is the drug-side equivalent if your product is not a device.
Exempt does not mean unregulated. Studies of FDA-regulated products still generally need IRB review and informed consent under Parts 50 and 56. For software-based products, read about software as a medical device. For practical study set-up, see how to run a medical device clinical study.
Getting started
Compare the intended use and the study against each 812.2(c) category, keeping the analysis in the study file.
Document why the device is or is not significant risk, with reference to 812.3(m).
Each investigator signs an agreement; the device carries the investigational caution statement.
The IRB reviews the protocol, consent and risk determination; an SR study waits for FDA as well.
Device accountability, adverse device effects and protocol endpoints need structured forms and an audit trail.
Draft eCRFs, export a blank eCRF PDF for the IRB and test edit checks in the free sandbox. No credit card, no time limit.
In Capture
Device studies mix site-entered data with what participants report. In Capture the same study can hold eCRFs for device performance and adverse device effects, ePRO questionnaires for symptoms or usability, and eConsent. Edit checks raise an auto-query when a site enters a value that breaks a rule, approved forms are locked for live use, and a blank eCRF PDF can be exported for the IRB package. The field-level audit trail records every change with the reason, which supports the records requirements a device sponsor has to meet.
Blank eCRF · no subject data
Visit by form matrix
| Form | SCR | D1 | W2 | W4 | W8 | EOS |
|---|---|---|---|---|---|---|
| Demographics | X | |||||
| Vital signs | X | X | X | X | X | X |
| Laboratory | X | X | X | |||
| ECG | X | X |
3. Was the ECG performed?
☐ Yes☐ No
If No, complete question 4.
An investigational device exemption allows an investigational device to be used in a clinical study in the US to collect safety and effectiveness data. The requirements are in 21 CFR Part 812.
No. Exempt studies under 812.2(c) are outside Part 812, and non-significant risk studies follow abbreviated requirements with IRB approval only. Only significant risk studies need an IDE application approved by FDA.
The sponsor makes an initial assessment and the IRB decides for the study. FDA can be asked for a determination and its decision is final.
They play similar roles, for devices and for drugs and biologics respectively. The rules differ: devices use investigator agreements rather than Form FDA 1572, and risk level decides whether FDA reviews an application.
Under 21 CFR 812.30 a significant risk investigation may begin 30 days after FDA receives the application unless FDA notifies the sponsor otherwise, for example with an approval, conditional approval or disapproval.
Often yes. Exemption from Part 812 does not remove the IRB and informed consent requirements of 21 CFR Parts 50 and 56 that apply to clinical investigations of FDA-regulated products.
Keep exploring
Significant risk device determination
Free SR vs NSR tool.
510(k), PMA and De Novo
Where IDE data end up.
How to run a medical device study
Practical set-up guide.
Early feasibility to pivotal device EDC
Data capture across device stages.
Post-market clinical follow-up
The EU after-approval counterpart.
Form FDA 1572
The drug-side investigator statement.
Free sandbox with every feature. Build forms, test edit checks and export a blank eCRF. No credit card, no time limit.