Glossary · Study designUpdated November 27, 2026

3+3 dose escalation design: how the rules work

The 3+3 design is a rule-based way to raise the dose in a phase 1 trial. Three patients are treated at a dose level, and the number with a dose-limiting toxicity (DLT) decides whether the next cohort goes up, the cohort is expanded to six, or escalation stops.

  • 3+3 design in plain language
  • How it works in practice
  • Related terms

Free sandbox · No credit card · 21 CFR Part 11 compliant

  • ISO 27001 certified
  • 21 CFR Part 11 compliant
  • GDPR compliant
  • EU and US data hosting
  • HIPAA compliant
  • ICH GCP E6(R3) compliant
Study design

3+3 design

noun · clinical research

A rule-based phase 1 dose escalation design that treats cohorts of three patients and expands to six when one has a dose-limiting toxicity. The maximum tolerated dose is the highest dose at which fewer than two of six patients have a DLT.

Related terms

Dose-limiting toxicityMaximum tolerated doseBOINCRMFirst-in-human

In short

  • 0 of 3 patients with a DLT: escalate to the next dose level. 1 of 3: treat three more at the same dose. 1 of 6: escalate. 2 or more (of 3 or of 6): the dose is too toxic and escalation stops.
  • The maximum tolerated dose (MTD) is declared as the highest dose at which fewer than two of six treated patients had a DLT, so the dose chosen must have six patients treated at it.
  • The design needs no statistical model and no software, which is why it was the default in oncology phase 1 for decades.
  • Its weaknesses are well documented: it does not aim at a chosen DLT rate, it uses only the current cohort’s data, and it often stops below the dose investigators were looking for.
  • Model-based and model-assisted designs such as CRM and BOIN address these weaknesses. To compare them numerically, use the dose escalation design calculator.

The rules

The exact 3+3 algorithm

A 3+3 study pre-specifies a ladder of dose levels, usually starting from a dose derived from non-clinical data (see first-in-human studies). Each dose level is first given to a cohort of three patients. Each patient is then followed through the DLT evaluation window that the protocol defines, often the first treatment cycle, and the safety review group counts how many had a dose-limiting toxicity. What counts as a DLT is a separate protocol decision, explained on the maximum tolerated dose and DLT page.

The decision after each cohort follows a fixed table. With 0 DLTs in 3 patients, the next cohort of three is treated at the next higher dose. With 1 DLT in 3, three more patients are treated at the same dose. If 1 of those 6 has a DLT, escalation continues; if 2 or more of the 6 do, the dose has exceeded the MTD. With 2 or more DLTs in the first 3, the dose has also exceeded the MTD and no expansion is needed.

When a dose exceeds the MTD, the trial steps back to the dose below. If only three patients were treated there, three more are added so the candidate MTD has six. The MTD is the highest dose at which no more than one of six patients had a DLT. Implicitly, the design treats an observed DLT rate between about 17% (1 of 6) and 33% (2 of 6) as the boundary, but the true rate at the declared MTD can be well outside that range because six patients carry very little information.

Variants you will see in protocols

Protocols adapt the basic rules. Some allow de-escalation below the starting dose. Some require a minimum number of patients at the MTD before an expansion cohort opens. Some add intra-patient escalation, or start with single-patient cohorts at very low doses (accelerated titration) and switch to 3+3 once a moderate toxicity appears. Others stagger the first patient in each cohort with an observation period, as described for sentinel dosing on the first-in-human page. Whatever the variant, the protocol must state it exactly, because the decision table is the design.

3+3 decision rules at one dose level
  1. Treat 3 patients

    Follow each through the DLT window

  2. 0 of 3 DLT

    Escalate to next dose level

  3. 3

    1 of 3 DLT

    Treat 3 more at the same dose

  4. 4

    1 of 6 DLT

    Escalate

  5. 5

    2+ of 3 or 2+ of 6

    MTD exceeded: step back one level

MTD = highest dose with at most 1 DLT in 6 treated patients.

Known weaknesses

Why statisticians criticise the 3+3 design

The appeal of 3+3 is transparency: any clinician can apply the rules at a safety meeting. The cost is that the design does not estimate anything. It does not let you choose a target toxicity rate, it ignores what happened at lower doses when deciding about the current one, and it treats a grade 3 event the same as a fatal one once both count as DLTs.

The arithmetic shows the problem. If a dose has a true DLT probability of 30%, the chance that 3+3 escalates past it is (0.7)³ + 3 × 0.3 × (0.7)² × (0.7)³, which is about 49%. At a true rate of 20% the chance of escalating is about 71%. So a dose that many oncology teams would consider acceptable is often declared too toxic, and the recommended dose ends up lower than intended. Because the MTD is based on six patients, its uncertainty is wide whichever way it falls.

Practical consequences

The weaknesses show up in day-to-day trial conduct as well as in the statistics.

  • Many patients are treated at low, possibly ineffective doses on the way up the ladder.
  • Late-onset toxicities after the DLT window do not change any decision.
  • The MTD says little about the dose with the best balance of benefit and risk, which matters more for targeted therapies and immunotherapies.
  • Cohorts are often waiting for the third patient’s window to close, which slows enrolment.
Chance that 3+3 escalates past a dose (exact calculation)
True DLT rateP(escalate)P(stop at or below)
Dose A10%91%9%
Dose B20%71%29%
Dose C30%49%51%
Dose D40%31%69%
Dose E50%17%83%
Illustrative dose labels. Values computed from the binomial formula, rounded.

Alternatives

3+3 compared with model-based and model-assisted designs

A conceptual comparison. For BOIN boundaries and exact 3+3 operating characteristics for your own dose ladder, run the dose escalation design calculator.

Feature3+3 (rule-based)CRM (model-based)BOIN (model-assisted)
Target DLT rate chosen in advanceNo, implied 17-33%YesYes
Uses data from all dosesNo, current cohort onlyYes, through a dose-toxicity modelCurrent dose, with optional isotonic estimate at the end
Decision rule at the bedsideFixed tableModel fit after each cohortPre-computed escalation and de-escalation boundaries
Statistical support neededMinimalOngoing, with model checksAt design stage, then a lookup table
Accuracy of MTD selectionLower in simulation studiesGenerally higherGenerally higher, similar to CRM
Explaining it to sites and ethics committeesVery easyHarderEasy

CRM: continual reassessment method. BOIN: Bayesian optimal interval design. Both are published statistical methods, not products.

Running one

How a 3+3 cohort moves through the trial

  1. 1

    Enrol and dose three patients

    Each patient is confirmed eligible against the inclusion and exclusion criteria and dosed at the current level. The dose level is recorded as data, not only in the pharmacy log.

  2. 2

    Follow each through the DLT window

    Adverse events are graded, usually with CTCAE (the CTCAE grade lookup is a quick reference), and assessed for relationship to the study drug.

  3. 3

    Adjudicate DLTs

    The investigator and medical monitor decide whether each qualifying event meets the protocol DLT definition, and whether each patient is DLT-evaluable.

  4. 4

    Hold the dose-escalation meeting

    The safety review group applies the decision table to the adjudicated counts and minutes the decision: escalate, expand to six, or step back.

  5. 5

    Open the next cohort

    The new dose level is released to sites only after the decision is documented, with the data snapshot that supported it.

Build your DLT and dose-level forms before the first cohort

Create the adverse event and DLT forms in the free sandbox, enter dummy patients at each dose level and check the audit trail. No credit card, no time limit.

Try Capture free

In Capture

Data that a dose-escalation meeting can trust

The 3+3 table is simple; the data feeding it is not. In Capture you build the dose-level, adverse event and DLT forms yourself, add edit checks that raise an auto-query when a site enters a value that breaks a rule, and keep a field-level audit trail with the old value, new value and reason for every change. Adverse event and laboratory eCRF templates are in the template library, and you can test the full build in the free sandbox before any patient is dosed.

  • Edit checks with auto-queries on safety values and dates.
  • Repeating rows for adverse events and concomitant medications, each with its own audit trail.
  • Exports with a data dictionary, plus SDTM datasets (SAS XPT with Define-XML).
EDC for phase 1 trials
DLT assessment
DEMO-101 · Subject 001-0042 · Dose level 3 · Cycle 1 Day 21Draft

Dose level

EXDOSLVL
Level 3

Any event meeting the protocol DLT definition?

DLTYN
YesNo

Worst CTCAE grade

AETOXGR
12345

Date of onset

AESTDTC
2026-03-14

DLT-evaluable

YesNo
Demo data only.Save
Onset date checked against the DLT window by an edit check.

FAQ

Common questions

Something not covered here? Ask us directly.

What does 3+3 mean in a clinical trial?

It describes the cohort sizes in a phase 1 dose escalation design: three patients are treated at a dose, and three more are added if one of the first three has a dose-limiting toxicity.

How is the MTD defined in a 3+3 design?

It is the highest dose level at which no more than one of six treated patients had a dose-limiting toxicity, with the next higher dose having two or more DLTs.

What happens if 2 of 3 patients have a DLT?

The dose is considered above the MTD. No more patients are treated there, and the trial goes back to the next lower dose, adding patients there if fewer than six were treated.

Is the 3+3 design still acceptable?

It is still used and still accepted by regulators and ethics committees, but many statisticians recommend model-based or model-assisted designs because they choose the MTD more accurately and treat fewer patients at low doses.

What is the difference between 3+3 and BOIN?

BOIN lets you choose a target DLT rate and gives escalation and de-escalation boundaries based on the observed rate at the current dose. 3+3 has a fixed table with an implied target. Both are easy to apply at a safety meeting.

Does the 3+3 design need a sample size calculation?

Not in the usual sense. Sample size depends on how many dose levels are explored and how often cohorts expand, so protocols give a range, for example the maximum number of patients if every level is expanded to six.

Dry-run your dose escalation build

Free sandbox with every feature. Add dose levels, DLT forms and edit checks, and test them with dummy patients. No credit card, no time limit.

Try Capture free