Tinnitus and hearing loss clinical trial EDC

Drug, injection and sound-therapy trials for the inner ear combine an audiogram for each ear at up to eight frequencies with a symptom only the participant can hear. Capture holds the thresholds, the daily tinnitus diary and the treatment log in one audit-trailed study. Build and test it free.

  • Audiogram 250 to 8000 Hz per ear
  • Daily loudness and annoyance diary
  • Range checks on every threshold

Free sandbox · No credit card · 21 CFR Part 11 compliant

  • ISO 27001 certified
  • 21 CFR Part 11 compliant
  • GDPR compliant
  • EU and US data hosting
  • HIPAA compliant
  • ICH GCP E6(R3) compliant

Daily tinnitus diary (demo)

Participant 003-0008 · Treatment week 3 · Day 5

How loud was your tinnitus today?

TINLOUD

0 = not heard, 10 = as loud as you can imagine

012345678910

How much did it bother you today?

TINANNOY
012345678910

Share of waking hours you were aware of it

TINAWARE
NoneUnder a quarterAbout halfMostAll

Where did you hear it?

TINLOC
Left earRight earBoth earsIn the head

Did it affect getting to sleep last night?

TINSLP
NoA littleA lot
Demo data only.Save
Five questions a day. Longer handicap questionnaires go at visits.

What a tinnitus or hearing loss trial needs from its EDC

  • The audiogram is a grid: air conduction thresholds in dB HL for each ear at 250, 500, 1000, 2000, 3000, 4000, 6000 and 8000 Hz, often bone conduction at 500 to 4000 Hz, and extended high frequencies above 8 kHz in ototoxicity studies.
  • Tinnitus is subjective: daily loudness and annoyance ratings, a visit-based handicap or functional-impact questionnaire, and psychoacoustic matching (pitch, loudness, minimum masking level) give three different views of the same symptom.
  • Hearing loss endpoints are threshold changes: recovery after sudden sensorineural hearing loss, or a shift from baseline in an ototoxicity prevention trial, measured against prespecified criteria.
  • The treatment is often local: intratympanic injections, devices or sound therapy need per-ear, per-session logs.
  • The pure-tone average is derived: it is not on Capture's calculated-field list, so frequencies are captured individually and the average is computed from the export.

The audiogram

Thresholds by ear and frequency, entered once and checked at entry

Build one section per ear with one numeric field per frequency, units in dB HL, and a range check (for example -10 to 120) that raises an auto-query when a value cannot be right. Add a "no response at audiometer limit" option per frequency; a missing response is not the same as a blank, and ototoxicity criteria treat a new loss of response as a shift. Record masking, the transducer (supra-aural, insert or circumaural headphones) and the audiometer calibration date, because a change of headphones between visits can look like a threshold shift. Tympanometry type and acoustic reflexes belong on the same visit if the protocol asks for middle-ear status.

The pure-tone average (commonly the mean of 500, 1000, 2000 and 4000 Hz, though protocols differ) is the number most people quote, but it is derived. Capture's calculated fields cover a fixed list of clinical formulas (BMI, BSA, MAP, eGFR, QTc, age, time between dates), and a pure-tone average is not on it. Capture every frequency as its own variable and compute the average and any shift criteria from the export, as the calculated fields help makes clear. That has an advantage: if the statistical plan changes which frequencies make up the average, nothing in the database needs to be re-entered.

Capture does not connect to audiometers. Results are typed by the audiologist or transcribed from the printout, per-field source data verification can be switched on for endpoint frequencies, and every correction keeps its audit trail with old value, new value and reason. If your study is about hearing devices (fitting, verification, wear time) rather than drugs or injections, start with EDC for hearing aid trials instead; the audiometry forms are similar, the rest of the study is not.

Air conduction audiogram, left ear (demo)
Participant 003-0008 · Day 28 · Right ear is the next sectionDraft

Thresholds (dB HL)

250 Hz

AC250L
15dB HL

500 Hz

AC500L
20dB HL

1000 Hz

AC1KL
25dB HL

2000 Hz

AC2KL
35dB HL

3000 Hz

AC3KL
45dB HL

4000 Hz

AC4KL
55dB HL

6000 Hz

AC6KL
60dB HL

8000 Hz

AC8KLNR
Threshold enteredNo response at limit

New loss of response since baseline (demo)

Test conditions

Transducer

AUDTRANS
Insert earphones

Masking used

AUDMASK
NoYes
Demo data only. Pure-tone average and shift criteria are computed from the export.Save
One variable per ear per frequency keeps the export ready for any average the statistical plan names.

Three common designs

How the data model changes by population

DesignTypical primary questionData that must be right
Chronic subjective tinnitusDoes a drug, device or sound therapy reduce tinnitus burden?Baseline diary weeks, handicap questionnaire at visits, psychoacoustic matching, hearing stable across the study
Sudden sensorineural hearing lossDoes treatment improve recovery of hearing?Onset date and time, days from onset to treatment, affected and unaffected ear audiograms, injection log
Ototoxicity prevention (otoprotection)Does a protective treatment reduce hearing loss from an ototoxic drug?Baseline before the first dose, audiograms per cycle, cumulative dose of the ototoxic drug, extended high frequencies, shift criteria
Hearing devices (separate page)Does a device or fitting improve hearing in daily life?Hearing aid trial page: fitting records and wear time

Measuring a symptom nobody else hears

Diary, questionnaire and psychoacoustic matching

Tinnitus loudness fluctuates day to day, so a single clinic rating is noisy. A daily diary of loudness and annoyance on a 0 to 10 scale, plus how much of the day the participant noticed it, gives a smoother baseline and a sensitive outcome. Run two to four weeks of baseline diary before treatment if the protocol allows, set an evening completion window and leave missed days missing. The diary opens from a secure link in the phone browser with email reminders; see patient diary software. A diary can show staff a summary across entries during the study; the change from baseline is computed from the export.

At visits, most trials add a validated tinnitus handicap or functional-impact questionnaire. Several widely used ones are copyrighted or carry conditions. Capture does not supply instruments or verify licences; on participant questionnaires you can record the licence number, holder and expiry, staff see a "copyright approval pending" watermark while details are missing, and after a recorded expiry no new tasks are generated. See questionnaire licences and ePRO for patient-reported outcome studies.

Psychoacoustic measures are performed by the audiologist: tinnitus pitch match in Hz, loudness match in dB SL at the matched frequency, minimum masking level in dB SL, and residual inhibition (none, partial, complete) with its duration in seconds. Pitch matching is notoriously variable, so many protocols repeat it and record each attempt as a row, then use the median. Hyperacusis and sound tolerance questions, sleep and mood scales are common secondaries. Treatment logs differ by modality: sound therapy needs a daily use log (minutes, programme), while neuromodulation needs session rows; see EDC for tDCS and TMS neuromodulation studies for session-level stimulation records.

Build the audiogram and the tinnitus diary, then enter a baseline

Create ear-by-frequency sections with range checks, a five-question daily diary with reminders, and export the data to test your average. Free sandbox, no credit card.

Build your hearing study free

Hearing loss endpoints

Sudden hearing loss, ototoxicity shifts and intratympanic treatment

Sudden sensorineural hearing loss is commonly defined as a loss of at least 30 dB over three consecutive frequencies developing within 72 hours, compared with a previous audiogram or the other ear. Trials therefore need the onset date and time, the time from onset to first treatment (often an eligibility limit), and audiograms of both ears at baseline, because the unaffected ear is often the reference for recovery. Recovery is then classified from later audiograms using criteria in the protocol (complete, partial, slight, none). Capture records the thresholds and dates; classification is computed from the export or entered by the audiologist as a separate field, and the protocol says which.

Ototoxicity prevention trials, for example in people receiving cisplatin, compare each follow-up audiogram with a baseline taken before the first dose. Criteria described in audiology reviews count a shift of 20 dB or more at one frequency, 10 dB or more at two adjacent frequencies, or a loss of response at three consecutive frequencies, confirmed on retest, and recommend extended high frequencies above 8 kHz where possible because loss often starts there. Children are graded with paediatric ototoxicity scales. Add a field where the audiologist records whether a shift from baseline was seen and confirmed on retest, so the clinical judgement is in the data with its audit trail; the formal grading against the criteria is done from the export. Record the ototoxic drug as a row per cycle with dose and date; the EDC for pediatric oncology clinical trials page covers the oncology side.

Intratympanic injection trials need a per-ear procedure log: ear, date, product volume in mL, anaesthetic used, time the head was kept turned, and procedure-related events such as pain, vertigo, otorrhoea or tympanic membrane perforation, with follow-up otoscopy. Vertigo and dizziness deserve explicit questions at each visit, not only spontaneous reporting. Adverse events go on the adverse event form with ear and relationship fields, and blinded roles never receive treatment-arm values, so the audiologist entering thresholds stays blind.

Protocol to build

Hearing and tinnitus assessments and the Capture form each one maps to

AssessmentWhat the data looks likeWhere it lives in Capture
Otological historyOnset date, laterality, noise exposure, ototoxic drugs, prior treatmentScreening form; medical history
Pure-tone audiogramdB HL per ear per frequency, no-response option, transducer, maskingSite eCRF, one section per ear, range checks, per-field SDV
Bone conduction and tympanometrydB HL 500 to 4000 Hz; tympanogram typeSame visit form, shown by skip logic
Speech audiometryWord recognition score in %, presentation levelRepeating row per ear and condition
Daily tinnitus diaryLoudness and annoyance 0 to 10, awareness, location, sleepePRO diary with reminders and a completion window
Tinnitus handicap questionnaireItem scores and totalePRO questionnaire with option scores; licence details recorded
Psychoacoustic matchingPitch Hz, loudness dB SL, minimum masking level, residual inhibitionRepeating row per attempt
Intratympanic or device treatmentEar, date, volume or settings, procedure eventsRepeating row per procedure or session
Ototoxic drug exposureAgent, cycle date, doseRepeating row per cycle
Adverse eventsVertigo, otalgia, perforation, worsening tinnitusAdverse event form

Pure-tone averages, threshold-shift grading and recovery categories are computed from the export unless the protocol has the audiologist enter them as fields.

Before first participant

Tinnitus and hearing loss study readiness checklist

Frequency list fixed

Conventional and extended frequencies, ears, bone conduction and units match the audiometer and protocol.

Average and shift rules written

Which frequencies make the average, which shift criteria apply and whether a retest is needed.

Baseline diary length set

Weeks of diary before treatment and minimum valid days per week.

Questionnaire licences filed

Rights-holder terms recorded for each tinnitus or hearing questionnaire.

Procedure log tested

A mock injection with a vertigo event entered and followed through to the adverse event form.

Export reviewed

Frequency variables opened in the statistics package and the pure-tone average reproduced.

FAQ

Questions teams ask before they switch

Something not covered here? Ask us directly.

Does Capture calculate the pure-tone average?

No. It is not on the calculated-field list. Each frequency is captured as its own variable and the average is computed from the export, which also lets the statistical plan choose the frequencies.

Can I record no response at the audiometer limit?

Yes. Add a no-response option per frequency so a missing response is a recorded result, not a blank.

Does Capture grade ototoxic threshold shifts?

No. Range checks catch impossible thresholds at entry, and the audiologist can record whether a shift was seen and confirmed on retest. Grading against the shift criteria is done from the export.

How is this different from the hearing aid trial page?

The hearing aid page covers devices: fitting, verification and wear time. This page covers drug, injection and sound-therapy trials for tinnitus, sudden hearing loss and ototoxicity, with daily diaries and treatment logs.

Can participants rate tinnitus daily on their phone?

Yes. The diary opens from a secure link in the phone browser with email reminders and a completion window, and missed days stay missing.

Does it connect to audiometers?

No integration is claimed. Thresholds are entered from the printout or audiometer screen, with a full audit trail and optional per-field SDV.

How much does it cost?

The sandbox is free with every feature and no credit card. You pay only when the study goes live; see the pricing page.

Start your hearing study free

Free sandbox with every feature. No credit card.

Build your hearing study free