A biosimilar programme does not try to show that a medicine works. It tries to show there is no meaningful difference from a reference biologic: same exposure, same response, same immune reaction. Capture holds the PK sample times, the equivalence endpoint, the antibody samples and the product lots in one audit-trailed study. Build and test it free.
Free sandbox · No credit card · 21 CFR Part 11 compliant
Comparative analytical assessment
Structure and function versus the reference product
Comparative PK study
Single dose, often healthy volunteers, parallel arms
Comparative efficacy study
Equivalence in a sensitive patient population, where still required
Immunogenicity assessment
ADA and neutralising antibodies across studies
Switching study
Only where a regulator still expects one
What a biosimilar study needs from its EDC
Biosimilar or bioequivalence?
| Topic | Small-molecule generic BE study | Biosimilar clinical programme |
|---|---|---|
| Product | Chemically identical active ingredient | Highly similar biologic made in living cells, with minor differences in inactive parts |
| Usual PK design | Two-period crossover in healthy volunteers | Often single-dose parallel arms, because many antibodies have long half-lives and may provoke antibodies |
| PK acceptance | 90% CI of the geometric mean ratio within 80.00 to 125.00% for AUC and Cmax | A similar 80 to 125% range is commonly used for PK similarity; confirm with your regulator |
| Efficacy study | Not needed | Comparative equivalence study in a sensitive population, where still required |
| Immunogenicity | Rarely relevant | ADA and neutralising antibodies at set times, linked to PK and safety |
| US pathway | Abbreviated new drug application | Section 351(k) of the Public Health Service Act; see the BLA glossary entry |
General summary only. Requirements are product specific; check current FDA and EMA guidance for your molecule.
Comparative pharmacokinetics
The comparative PK study is usually the first clinical study in a biosimilar programme and often the most decisive. For many monoclonal antibodies it is a single-dose, parallel-group study in healthy volunteers, because a long half-life makes a crossover impractical and a second exposure could be affected by antibodies from the first. Where a product is too toxic for healthy volunteers, such as some oncology antibodies, PK is assessed in patients instead. Primary parameters are commonly AUC from zero to infinity and Cmax, with the 90% confidence interval of the geometric mean ratio expected inside a margin such as 80 to 125%; your agreed protocol sets the exact rule.
The data that makes or breaks the analysis is time. Record the infusion or injection start and stop clock times, the injection site, the nominal sample time and the actual sample time for every draw. A calculated field can show the minutes or hours between dose and sample during entry, and an edit check on that field raises a query when a draw falls outside the allowed window. Many programmes compare the proposed biosimilar with the reference product as sourced in two regions (for example a US-licensed and an EU-approved reference) in a three-arm study; store the arm, product source and lot number on every dose record. Capture does not calculate PK parameters; concentration results and times go out in the export to your PK software.
Healthy volunteer logistics are their own topic: confinement days, meal timing, alcohol and caffeine restrictions and screening labs. See EDC for healthy volunteer studies for that side of the study, and the Phase 1 clinical trial EDC page for dose administration records.
Dose
Product source
EXSRCLot number
EXLOTInjection start date-time
EXSTTMSample
Nominal time point
PKTPTActual sample time
PKTMHours since dose
PKELTMQuery: outside the window set for the 6 h sample (demo)
Comparative efficacy
Where a comparative efficacy study is required, it is usually a randomised, double-blind equivalence trial in a population sensitive enough to show a difference if one exists: for example a response rate in a chronic inflammatory disease, a change in a skin score in psoriasis, or a response rate in a cancer setting. The question is whether the difference between products sits inside a pre-specified two-sided margin. That has consequences for data: poor adherence, missed assessments and protocol deviations make two products look more alike, which in an equivalence trial is the wrong direction to be biased. Track dosing, deviations and missing visits as carefully as the endpoint itself, using the protocol deviation tracking and visit windows set up for the study.
Blinding is harder than it looks because the products may differ in device, label or appearance. Many teams use an unblinded pharmacist or nurse who prepares the dose, while investigators and assessors stay blinded. In Capture, blinded roles never receive treatment-arm values, which is enforced in the database rather than only on screen, and kit lists, dispensing and accountability are recorded per kit; see blinded and unblinded role management and the help article on dispensing kits. For sizing, the equivalence trial sample size calculator uses two one-sided tests against your margin.
Regulators have recently signalled that comparative efficacy studies may not be needed for every biosimilar when analytical and PK data are strong. Check the current FDA and EMA guidance for your product class before you commit to the size and cost of an efficacy study.
Immunogenicity and switching
Immunogenicity is assessed in a tiered way: a screening assay, a confirmatory assay for screening-positive samples, a titre for confirmed positives, and a neutralising antibody assay. The sample schedule is fixed in the protocol: a pre-dose baseline, several time points during treatment (often at trough, just before the next dose, to limit drug interference with the assay) and an end-of-study or follow-up sample. Build a sample collection form with the nominal time point, the actual date and time and the time of the last dose, and a result form with one field per tier, so a positive confirmatory result without a titre is visible as a gap. Link the ADA status to PK and to adverse events such as hypersensitivity and injection site reactions, which are often the safety signals regulators look at first.
Switching designs randomise participants to stay on the reference product or to alternate between reference and biosimilar several times, with PK after the last switch as a common primary endpoint and immunogenicity and safety as key secondaries. In the US such studies have been linked to interchangeability designation. FDA has recently signalled (in 2024 draft guidance) that switching studies are generally not expected for interchangeability; check the current FDA position before planning one. In the EU, regulators have stated that approved biosimilars are interchangeable with their reference product. For a switching study, store the sequence and every product change as dated rows, so the export shows each participant's full exposure history.
| Assessment | Wk 0 | Wk 2 | Wk 4 | Wk 6 | Wk 8 | Wk 10 | Wk 12 | Wk 14 |
|---|---|---|---|---|---|---|---|---|
| Product given | Ref | Ref | Bio | Bio | Ref | Ref | Bio | Bio |
| ADA / NAb sample (trough) | ||||||||
| PK sampling (after last switch) | ||||||||
| Injection site and hypersensitivity check | ||||||||
| Adverse events |
Ref = reference product, Bio = proposed biosimilar, x = sample or form at the visit.
Add nominal and actual times, an elapsed-time query, lot numbers and blinded roles. Free sandbox, no credit card.
Protocol to build
| Data | What it looks like | Where it lives in Capture |
|---|---|---|
| Dose administration | Product, source region, lot, start and stop times, site of injection | Repeating dose rows; kit dispensing and accountability |
| PK samples | Nominal and actual time, hours since dose, concentration from the bioanalytical lab | Sample log with a calculated elapsed time and window check |
| Immunogenicity | Screening, confirmatory, titre and neutralising results per sample | Sample form plus a tiered result form |
| Efficacy endpoint | Response status or score change at the primary time point | Site eCRF or ePRO, per the indication |
| Hypersensitivity and injection site reactions | Onset, severity, action taken | Adverse event form with extra fields |
| Switching sequence | Product at each dose, date of each switch | Dated rows, one per dose |
| Randomisation and blinding | Arm, stratum, blinded and unblinded roles | Randomisation with masked database views |
Capture does not calculate AUC, Cmax, geometric mean ratios or confidence intervals. These are calculated from the export.
Build sequence
The AI study builder drafts visits and forms from a PDF, DOCX or DOC protocol. A person reviews every draft before it is saved.
Biosimilar and each reference source as kit types, with lot numbers on every dose row.
Dose times, PK sample log with nominal and actual times, and an elapsed-time window check.
Sample collection form on the protocol schedule and a tiered result form.
Strata, blinded roles and an unblinded preparer role.
Enter a late sample, a missing titre and a switch, then check queries and the export. Approved forms lock for live use.
Before first participant
Which studies FDA and EMA expect for this product, checked against current guidance.
PK similarity range and efficacy equivalence margin fixed in the protocol and statistical plan.
Allowed deviation for each nominal PK and ADA time point.
Regions, lots and expiry for each reference product.
Who prepares doses, who assesses outcomes, and who sees which data.
PK and ADA data opened in the analysis tools; SDTM available if needed.
A bioequivalence study compares a chemically identical generic, usually in a crossover. A biosimilar programme compares a large, variable biologic, often with a parallel PK study, an equivalence efficacy study where required and a full immunogenicity assessment. See the bioequivalence page.
Yes. Record nominal and actual times; a calculated field shows hours since dose during entry, and an edit check raises a query when a sample is outside its window.
No. Concentrations and times are exported to your PK software, which calculates the parameters and the confidence intervals.
As a tiered result form per sample: screening, confirmatory, titre and neutralising. Each result keeps its own audit trail.
FDA has signalled that switching studies are generally not expected, and EU regulators treat approved biosimilars as interchangeable. Check the current position with your regulator before planning one.
Yes. Use an unblinded role for dose preparation. Blinded roles never receive treatment-arm values, enforced by masked database views.
The sandbox is free with every feature and no credit card. You pay only when the study goes live; see the pricing page.
Keep exploring
EDC for bioequivalence studies
Small-molecule generics and crossover BE.
BLA glossary entry
351(a) and 351(k) pathways.
Equivalence sample size calculator
Two one-sided tests against a margin.
EDC for healthy volunteer studies
Confinement, meals and screening labs.
Blinded and unblinded roles
Who sees the arm.
EDC for psoriasis trials
A common biosimilar efficacy population.
Free sandbox with every feature. No credit card.