Investigational product has to be stored as the sponsor specifies, and you have to be able to prove it. This template covers the daily min/max log, the excursion report, quarantine and the sponsor assessment that decides whether the product can still be used.

  • Daily min/max log columns
  • Excursion report fields
  • Quarantine and release steps

Free sandbox · No credit card · 21 CFR Part 11 compliant

  • ISO 27001 certified
  • 21 CFR Part 11 compliant
  • GDPR compliant
  • EU and US data hosting
  • HIPAA compliant
  • ICH GCP E6(R3) compliant
Quarantine kit · K-10482
Site 003 · Pharmacy fridge F-02 · Demo studyAvailable at site

Action

Action

QuarantineMark unusable

Reason category

Temperature excursion

Description

At least 10 characters

Fridge F-02 max 9.4 °C overnight (range 2–8 °C). Logger data sent to sponsor. Excursion report TE-003-02.

Signature

Password

••••••••
Sign to quarantine · cannot be dispensed until releasedSave
Demo kit and values

Key points

  • Under ICH E6(R2) 4.6.4, investigational product is stored as specified by the sponsor and in line with applicable regulatory requirements. The temperature log is your evidence that it was.
  • Record the current, minimum and maximum temperature at least once each working day, then reset the min/max memory. Current temperature alone misses what happened overnight and at weekends.
  • An excursion is any reading outside the labelled storage range. The site does not decide whether the product is still usable: it quarantines, documents and asks the sponsor.
  • The excursion report records when it started, how long it lasted, the peak or lowest value, which kits were affected and what was done. Logger downloads are the best source for duration.
  • Kit custody belongs in the IMP accountability log; temperature belongs here. Cross-reference both.

Purpose

Why the temperature log is an essential document

The investigator, or a pharmacist the investigator delegates to, is responsible for accountability of investigational product at the site. ICH E6(R2) 4.6.3 expects records of delivery, inventory, use by each participant and return or destruction, and 4.6.4 expects storage as the sponsor specifies. The storage conditions are on the label and in the pharmacy manual: often refrigerated at 2–8 °C, controlled room temperature within a labelled range, or frozen. Your log shows that every day the product was on site, it was inside that range, or that you noticed when it was not.

Monitors check the log at every on-site visit, and gaps are a common finding: weekends with no entry, min/max memory never reset, a thermometer with an expired calibration certificate, an excursion noted in the log with no report behind it. Each of those undermines the claim that the product given to participants was fit for use. If a deviation results, record it in the protocol deviation log at site level.

For where the log is filed, see the investigator site file index. Many sites now use continuous data loggers with alarms. They are better at catching short excursions and give you duration directly. Keep a daily human review anyway, because an alarm that goes to an empty inbox is not oversight.

Template part 1

Daily temperature log columns

One log per storage unit (fridge, freezer, room or cabinet). Put the unit ID, location, labelled range, thermometer or logger ID and calibration expiry in the header.

ColumnWhat to enterExample
DateEvery day product is stored; mark weekends and holidays as covered by logger download if nobody reads on site.24 Nov 2026
Time of readingSame time each day where possible.08:40
Current temperatureReading at the time of check, with unit.4.6 °C
Minimum since last resetFrom the min/max display or logger.3.1 °C
Maximum since last resetFrom the min/max display or logger.6.9 °C
Within range?Yes or no against the labelled range.Yes
Min/max reset doneTick after resetting the memory.Yes
Read byInitials of a delegated person.JO
Excursion report refOnly if out of range.—
CommentDoor left open, power cut, defrost, alarm test.Alarm tested, OK

If your unit has a continuous logger, download and review it at a fixed interval (for example weekly and after every weekend) and file the printout or file reference with the log.

Template part 2

Temperature excursion report fields

Complete one report per excursion event, not per kit. Send it to the sponsor with the logger data and wait for the assessment before using any affected product.

FieldWhat to enterGuidance
Report IDSite number plus running number.TE-003-02
Storage unit and locationUnit ID, room, labelled range.Fridge F-02, pharmacy, 2–8 °C
Detected by and whenWho noticed, how (daily read, alarm, logger review), date and time.Pharmacist, daily read, 25 Nov 08:35
Start and end of excursionFrom logger data if available; otherwise last in-range and first out-of-range reading.24 Nov 23:10 to 25 Nov 06:50
Duration out of rangeHours and minutes.7 h 40 min
Highest or lowest valuePeak or trough reached.9.4 °C
Probable causePower failure, door, compressor, defrost cycle, unknown.Door not fully closed after evening stock check
Product affectedKit numbers, lot or batch, quantities.K-10480 to K-10489 (10 kits), lot L2207
Immediate actionQuarantine, move to back-up unit, label “Do not use”.Kits quarantined in F-03, labelled
Sponsor notifiedDate, time, how, to whom.25 Nov 09:10 by email to study pharmacist
Sponsor assessmentDecision and reference: use, do not use, return.Usable, stability data cover excursion; ref 25 Nov
Final dispositionReleased, returned or destroyed, with date and signature.Released 26 Nov, JO
Preventive actionWhat changes; CAPA ref if needed.Door alarm enabled; CAPA-009

Do not average readings or round down to bring a value back into range. Report what the instrument recorded.

Worked example

Working out duration and impact for an overnight excursion

At 08:35 on Wednesday the pharmacist reads fridge F-02: current 7.2 °C, minimum 3.0 °C, maximum 9.4 °C. The maximum is outside the 2–8 °C range, so there has been an excursion even though the current value is back in range. That is why the minimum and maximum columns exist.

The logger download shows the temperature crossed 8.0 °C at 23:10 on Tuesday, peaked at 9.4 °C around 02:00 and dropped below 8.0 °C at 06:50, so the excursion lasted 7 hours 40 minutes. Ten kits from one lot were in the unit. The pharmacist quarantines them in the back-up fridge, completes report TE-003-02 and sends it with the logger file to the sponsor. The sponsor compares the excursion against the product’s stability data and replies the next day that the kits remain usable. The pharmacist releases them (in a kit system, the step described in kit accountability), records the decision and its reference on the report, and opens a CAPA because the cause, a door not fully closed, could recur.

If the sponsor had said the product could not be used, the kits would be marked unusable and returned or destroyed under the sponsor’s instructions, with a deviation logged if any participant had already received product from the affected stock.

Fridge F-02 daily log, one week (demo)
CurrentMinMaxIn range
Mon 23 Nov4.83.26.1
Tue 24 Nov4.63.16.9
Wed 25 Nov7.23.09.4
Thu 26 Nov4.93.46.3
Fri 27 Nov5.03.36.0
Values in °C. Wednesday’s max triggers report TE-003-02

Excursion handling

What to do the moment you find an excursion

  1. 1

    Stop using the affected product

    Do not dispense from the unit until you know which kits were inside. If a participant is due a dose today, call the sponsor before the visit.

  2. 2

    Quarantine and label

    Move the product to a working unit at the correct temperature, physically separated and labelled “Quarantine, do not use”.

  3. 3

    Secure the evidence

    Download the logger, photograph the display, and do not reset the min/max until you have recorded it.

  4. 4

    Fill the excursion report

    Start, end, duration, extreme value, kits affected, cause, action. Facts only.

  5. 5

    Notify the sponsor

    Within the timeline in the pharmacy manual, with the report and logger data.

  6. 6

    Act on the sponsor decision

    Release, return or destroy as instructed, and record the decision reference. Never decide usability yourself.

  7. 7

    Prevent recurrence

    Fix the cause; open a CAPA if it could recur. Log a deviation if the protocol or pharmacy manual requires it.

Walk a kit through quarantine and release

In the free sandbox you can load sample kits, receive a shipment, quarantine a kit for a temperature excursion and see it blocked from dispensing until it is released.

Start free

In Capture

The kit side of an excursion, signed and traceable

Capture does not read your thermometer or logger; the daily temperature log stays with your pharmacy records. What Capture holds is the product side. When a shipment arrives, site staff tick the kits that arrived in good condition, and any kit left unticked is quarantined with a reason such as temperature excursion. Any kit can later be quarantined or marked unusable from its lifecycle badge, with a reason category, a description and a password signature. Quarantined kits cannot be dispensed until someone at the site releases them, and the dispensing checks include storage conditions.

  • Quarantine at receipt with “temperature excursion” as the reason (receiving a shipment).
  • Quarantine or mark unusable later, signed with your password.
  • Reversing an unusable kit needs two signatures.
  • Every step in the kit history and audit trail, ready for reconciliation.
IMP inventory and drug accountability software

Kit K-10418 · custody history

  1. At depotAvailable
  2. In transitAvailable
  3. At siteAssigned
  4. With patientDispensed
  5. ReturnedReturned (used)
  6. DestroyedDestroyed

Only physically possible combinations can be saved.

Before a monitoring visit

Temperature log checklist

Header complete

Unit ID, location, labelled range, thermometer or logger ID, calibration expiry.

No unexplained gaps

Weekends and holidays covered by logger review, with a record.

Min and max recorded and reset

Every reading, not only current temperature.

Calibration in date

Certificate on file for each thermometer or logger.

Every out-of-range value has a report

Report ID written on the log line.

Sponsor decision on file

For every excursion, with the release or disposal record; see IMP inventory software for the kit side.

Readers are delegated

Initials match the delegation log.

Back-up unit and plan

Where product goes if the main unit fails, and who is called out of hours.

FAQ

Questions about this template

Something not covered here? Ask us directly.

What should a temperature log for clinical research include?

A header with the storage unit, location, labelled range and thermometer or logger details, then a daily row with date, time, current, minimum and maximum temperature, whether it was in range, min/max reset, initials, and an excursion report reference when needed.

How often should IP storage temperatures be recorded?

At least once each working day is the common minimum, with a continuous logger reviewed for weekends and holidays. Follow the frequency in the sponsor’s pharmacy manual if it sets one.

What is a temperature excursion?

Any time the storage temperature goes outside the range on the product label or in the pharmacy manual, however briefly. Short excursions still need to be recorded and reported to the sponsor.

Can the site decide whether product is still usable after an excursion?

No. The site quarantines the product, documents the excursion and sends the data to the sponsor, who assesses it against stability data and decides whether it can be used.

Why record minimum and maximum, not just the current temperature?

Because an excursion can happen and resolve between two readings, overnight or at a weekend. Only the min/max memory or a logger will show it.

Is a temperature excursion a protocol deviation?

It depends on the protocol and the sponsor’s rules. Many sponsors treat it as a deviation if affected product was dispensed or if storage requirements in the protocol were not met. Record it in the deviation log when required.

Does Capture record fridge temperatures?

No. Capture does not connect to thermometers or loggers. It records the product side: quarantine at receipt or later with a temperature-excursion reason, signed release, and a full kit history.

Track every kit, including the quarantined ones

Load sample kits and try receipt, quarantine and release. Free sandbox, no credit card.

Start free